Introduction - If you have any usage issues, please Google them yourself
"angle measuring device" using photoelectric encoder measurement perspective, each pulse of 0.72 degrees. Measuring range : 0.0 to 360.0 degrees to ensure the well-off pulse, with timer1 count, in Level Trip interruption Lane judge the direction of rotation, to speed up the process. Data conversion and digital control display in the main scanning cycle to achieve. Decoding the Formosan 10-meter-long five core shield wire with a few significant for the two Bit link. MCU for the 12F629, the use of 4 megabytes of internal RC oscillation and internal reset function.