Location:
Search - IEC-60870-5-2
Search list
Description: 远动设备及系统第5部分传输规约:IEC-60870-5-1、IEC-60870-5-2、IEC-60870-5-3、IEC-60870-5-4、IEC-60870-5-5、IEC-60870-5-101、IEC-60870-5-104、术语表、应用分析。
Platform: |
Size: 4124860 |
Author: yuymg |
Hits:
Description: 此文件为电力通信101规约链路层源码,应用层代码视不同应用而定所以无需上载-this document to the Statute 101 power communication link layer source, the application layer, depending on application code which there is no need to upload
Platform: |
Size: 5120 |
Author: 阿牛 |
Hits:
Description: 著名的IEC60870-5-103的实现源代码-famous IEC60870-5-103 to achieve the source code
Platform: |
Size: 17408 |
Author: 胡永春 |
Hits:
Description: 电力系统103规约源代码
本规约参考了IEC60870-5-103(继电保护设备信息接口配套标准)传输规约(以下简称103规约),针对不同的网络结构,提出了2种链路传输方式,但都采用103规约的应用服务数据单元。根据103规约的要求,新研制的保护、测量、控制设备必须采用该配套标准的兼容范围,不能满足的部分采用通用分类服务完成。因此本协议适用于新研制的产品。-power system 103 of the Statute, the Statute of the source code reference to the IEC60870-5-103 (relay Bao Information security equipment interface supporting standard) transmission protocol (hereinafter referred to the Statute of 103) for different network structure, the two types of transmission methods, but they all use 103 of the Statute of application service data units. According to the Statute 103, a newly developed protection, measurement, control equipment must adopt the standards of compatibility matching, unable to meet part of a universal classification completed. Therefore the agreement applicable to the development of new products.
Platform: |
Size: 117760 |
Author: 王庆华 |
Hits:
Description: IEC60870-5-103规约测试工具。
目前只能打开COM1口,(呵呵)有兴趣的可以更改。-IEC60870-5-103 Statute testing tools. At present, I can only open the COM1 (Ha ha) are interested can change.
Platform: |
Size: 141312 |
Author: 龙啸天 |
Hits:
Description: 远动设备及系统第5部分传输规约:IEC-60870-5-1、IEC-60870-5-2、IEC-60870-5-3、IEC-60870-5-4、IEC-60870-5-5、IEC-60870-5-101、IEC-60870-5-104、术语表、应用分析。-Telecontrol equipment and systems Part 5 Transfer Protocol: IEC-60870-5-1, IEC-60870-5-2, IEC-60870-5-3, IEC-60870-5-4, IEC-60870-5-5 , IEC-60870-5-101, IEC-60870-5-104, Glossary, application analysis.
Platform: |
Size: 4124672 |
Author: yuymg |
Hits:
Description: IEC60870-5-103通讯规约,国电南端继保公司-IEC60870-5-103 communication Statute, State Power, following the southern tip of insurance companies
Platform: |
Size: 9216 |
Author: taozj |
Hits:
Description: Contains IEC documents describing testing implementations of IEC 60870-5, amendment to IEC 60870-5-104, and GBC reports helping faster understand the standard
Platform: |
Size: 948224 |
Author: sor |
Hits:
Description: This is source code for library of IEC 60870-5-101 master included in "Lib870-5Demo". Disasmed with IDA-This is source code for library of IEC 60870-5-101 master included in Lib870-5Demo . Disasmed with IDA
Platform: |
Size: 13312 |
Author: sor |
Hits:
Description: OPC Client 源代码,支持OPC 2.0
非常有参考价值-OPC Client source code, OPC 2.0 support is very useful
Platform: |
Size: 2042880 |
Author: zhangyi |
Hits:
Description: 103协议的详细介绍,对于电力系统相关的自动化设备研发有帮助-A detailed description of protocol 103, for power system automation equipment-related R & D has to help
Platform: |
Size: 685056 |
Author: power |
Hits:
Description: IEC 61850 Demo, client and server applications, partially in Chinese language I suppose.
Platform: |
Size: 1620992 |
Author: jfalkows |
Hits:
Description: IEC 870-5-104 Slave example (EXE)
Platform: |
Size: 792576 |
Author: toschkin |
Hits:
Description: IEC 60870-104 Master C++ Library
Platform: |
Size: 1227776 |
Author: ale75 |
Hits:
Description: IEC 101 document in pdf file format
Platform: |
Size: 1107968 |
Author: myemail |
Hits:
Description: IEC 60870-5-101 inRussian
Platform: |
Size: 9015296 |
Author: vem |
Hits:
Description: IEC60870-5-5104 international standard
Platform: |
Size: 566272 |
Author: Saeed |
Hits:
Description: International Standard IEC 60870-5-104 (2006)
Telecontrol equipment and systems –
Part 5-104:
Transmission protocols –
Network access for IEC 60870-5-101
using standard transport profiles
Platform: |
Size: 771072 |
Author: P. van Dijk |
Hits:
Description: 使用在IEC60870-5中指定的远程控制消息协议来模拟系统的服务器端。-This IEC Server in an Software to simulate Server side of Systems using an telecontrol message Protocol specified in the IEC 60870-5:
Platform: |
Size: 390144 |
Author: wanglina |
Hits: