Welcome![Sign In][Sign Up]
Location:
Search - IEEE Feeder

Search list

[AlgorithmStateestimationindistributiongrids

Description: observable distribution grid are investigated. A distribution grid is observable if the state of the grid can be fully determined. For the simulations, the modified 34-bus IEEE test feeder is used. The measurements needed for the state estimation are generated by the ladder iterative technique. Two methods for the state estimation are analyzed: Weighted Least Squares and Extended Kalman Filter. Both estimators try to find the most probable state based on the available measurements. The result is that the Kalman filter mostly needs less iterations and calculation time. The disadvantage of the Kalman filter is that it needs some foreknowlegde about the state.
Platform: | Size: 253952 | Author: chowzaisun | Hits:

[Otherfeeder13

Description: 这些测试的一个程序来代表不同的配置,全系三相变压器的能力,和不平衡负载。-These test the capability of a program to represent transformers of various configurations, full three phase lines, and unbalanced loads.
Platform: | Size: 49152 | Author: tsaic23 | Hits:

[matlab1

Description: ieee distribution test feeder
Platform: | Size: 1024 | Author: mosi | Hits:

[Windows DevelopIEEE-bus-feeder-saSharp

Description: IEEE bus feeder 34 model for PSCAD SOFTWARE-IEEE bus feeder 34 model for PSCAD SOFTWARE....
Platform: | Size: 12288 | Author: xxxddd | Hits:

[matlabproyecto

Description: this a test fil for ieee node test feeder-this is a test fil for ieee node test feeder
Platform: | Size: 2048 | Author: rserrac | Hits:

[Software Engineeringfeeder4_IEEE

Description: IEEE 4 nodes feeder test data
Platform: | Size: 77824 | Author: tarik | Hits:

[OtherRobust--control

Description: Distributed Robust Adaptive Frequency Regulation of Power Grid with Renewable Integration. Simulations on the IEEE PES Distribution 37 bus test feeder topology are conducted to demonstrate the ectiveness of the proposed controllers.
Platform: | Size: 586752 | Author: 费汪浩 | Hits:

[Search Engine4

Description: FEEDER test 4 node ieee
Platform: | Size: 76800 | Author: slim | Hits:

[OtherIEEE-Transactions-Optimal-Distribution-Feeder-Rec

Description: Optimal Distribution Feeder Reconfiguration for Reliability Improvement Considering Uncertainty
Platform: | Size: 1868800 | Author: ibrahim sultan | Hits:

[OtherIEEE_9bus

Description: bus this the updated version of IEEE Feeder 9
Platform: | Size: 539648 | Author: awili | Hits:

[Otherfeederrrr4 you

Description: system for analize feeder of 37 buss ieee
Platform: | Size: 76800 | Author: yogaugusta | Hits:

[ApplicationsYYD_4node_testfeeder

Description: IEEE Test feeder for PSCAD softawre
Platform: | Size: 104448 | Author: qasim787 | Hits:

[Otherfeeder13

Description: IEEE 13 bus feeder data from power system archive
Platform: | Size: 49152 | Author: Anees | Hits:

[Software Engineering1815-2012 - IEEE Standard for Electric Power Systems Communications-Distributed Network Protocol (DNP3) - Redline

Description: The DNP3 protocol structure, functions, and interoperable application options (subset levels) are specified. The simplest application level is intended for low-cost distribution feeder devices, and the most complex for full-featured systems. The appropriate level is selected to suit the functionality required in each device. The protocol is suitable for operation on a variety of communication media consistent with the makeup of most electric power communication systems.
Platform: | Size: 29704699 | Author: sl_secret@yahoo.com | Hits:

CodeBus www.codebus.net