Description: 有源滤波器(APF)matlab_simulink仿真图的子图之一。算法是DQ0 算法。-active filter (APF) matlab_simulink simulation map one of the graph. The algorithm is DQ0 algorithm. Platform: |
Size: 5120 |
Author:王晓光 |
Hits:
Description: SIMULINK的仿真图,用于电力系统谐波抑止的,有些环境可能不兼容。-SIMULINK simulation diagram for power system harmonics curbed, and some may not be compatible with the environment. Platform: |
Size: 13312 |
Author:ian |
Hits:
Description: 一篇学位论文,基于DSP的电力有源滤波器研究。用matlab仿真,并设计了模拟电路。-Write a dissertation, DSP-based Active Power Filter. Using matlab simulation, and design analog circuits. Platform: |
Size: 2070528 |
Author:单世超 |
Hits:
Description: 基于SIMULINK搭建的并联有源电力滤波器程序,希望大家,相互交流。-SIMULINK-based structures of Shunt Active Power Filter procedures, hope, each other. Platform: |
Size: 16384 |
Author:ian |
Hits:
Description: 3 phase Active Power filter that is simulated in matlab simulink based on hysteresis current control method Platform: |
Size: 16384 |
Author:khalilg |
Hits:
Description: The PV array has been simulated at one year period and other code sources are
been discussed. In order to extract the voltage deviation from the array, we intent to
apply the formula of the MPP to these codes. Our approach, considering the hole
system, has not been totally implemented in Simulink. The grid utility and the control Platform: |
Size: 393216 |
Author:mimo |
Hits:
Description: 基于谐波电流快速检测方法的有源电力滤波器simulink仿真模型
-Current rapid detection methods based on harmonic active power filter simulink simulation model Platform: |
Size: 14336 |
Author:流沙 |
Hits:
Description: 有源电力滤波器,可以使用。是一种应用滞环的有源电力滤波器,matlab simulink平台。-Active power filter can be used. Hysteresis is an application of Active Power Filter, matlab simulink platform. Platform: |
Size: 9216 |
Author:贾明波 |
Hits:
Description: This paper proposes an open switch faults detection and localization algorithm for shunt three
phase active filter topology. It mainly details converter configuration and examines a simple and
reliable optimised fault diagnosis method. The con verter topology is based on classical three-leg
active power filter topology. A ne w fault diagnosis method is proposed, based on classical
currents measurements. It includes combinatory logic to analyse and validate error signals. A
Hysteresis Control is applied before and after fault detection, which avoids any controller
reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the
effectiveness of this method. -This paper proposes an open switch faults detection and localization algorithm for shunt three
phase active filter topology. It mainly details converter configuration and examines a simple and
reliable optimised fault diagnosis method. The con verter topology is based on classical three-leg
active power filter topology. A ne w fault diagnosis method is proposed, based on classical
currents measurements. It includes combinatory logic to analyse and validate error signals. A
Hysteresis Control is applied before and after fault detection, which avoids any controller
reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the
effectiveness of this method. Platform: |
Size: 314368 |
Author:nek |
Hits:
Description: A control algorithm for a three-phase hybrid power filter is proposed. It is constituted by a series active filter and a passive
filter connected in parallel with the load. The control strategy is based on the vectorial theory dual formulation of instantaneous
reactive power, so that the voltage waveform injected by the active
filter is able to compensate the reactive power and the load current
harmonics and to balance asymmetrical loads. The proposed algorithm also improves the behavior of the passive filter. Simulationshave been carried out on the MATLAB-Simulink platformwith different loads and with variation in the source impedance.This analysis allowed an experimental prototype to be developed.
Experimental and simulation results are presented. Platform: |
Size: 1004544 |
Author:khan |
Hits:
Description: 使用simulink构建带谐波的三相电路,使用有源滤波器APF进行谐波抑制研究(A three-phase circuit with harmonics is constructed with Simulink, and the study of harmonic suppression using active filter APF) Platform: |
Size: 13312 |
Author:josdgv
|
Hits:
Description: In this paper, an efficient active power filter (APF) scheme is developed to estimate and compensate for harmonic distortion in an electrical power network. The developed APF control scheme is based on a double proportional feedback controller and a single-phase voltage-source half-wave bridge inverter. The proposed filter uses a Multi-layer Artificial Neural Network (MLANN) with a shift method for estimating system harmonic currents and voltages at a dedicated point. The proposed scheme is tested on a 13 bus industrial distribution system. The obtained results ensure the effectiveness of the proposed filter. The system is simulated in MATLAB-Simulink and simulation results prove that the polluting harmonics have been greatly reduced. Platform: |
Size: 1906688 |
Author:amir1 |
Hits: