Description: 基于谐波电流快速检测方法的并联型有源电力滤波器设计。用于毕业设计-Harmonic Current Detection Method Based Shunt Active Power Filter. For graduation Platform: |
Size: 4926464 |
Author:杨强 |
Hits:
Description: 基于谐波电流快速检测方法的并联型有源电力滤波器设计 不错的 可以做毕业设计-Harmonic Current Detection Method Based Shunt Active Power Filter can do a good graduation Platform: |
Size: 4582400 |
Author:杨强 |
Hits:
Description: 并联型电力有源滤波器的仿真。提出了并联有源电力滤波器的模型,并进行仿真,最后给出了与实验相一致的结果。-Shunt Active Power Filter. Proposed shunt active power filter model and simulation, are given with the experimental results. Platform: |
Size: 467968 |
Author:单世超 |
Hits:
Description: 基于SIMULINK搭建的并联有源电力滤波器程序,希望大家,相互交流。-SIMULINK-based structures of Shunt Active Power Filter procedures, hope, each other. Platform: |
Size: 16384 |
Author:ian |
Hits:
Description: 并联型有源电力滤波器的PSIM仿真研究Shunt Active Power Filter PSIM simulation-Shunt Active Power Filter PSIM simulation Platform: |
Size: 243712 |
Author:beijing001 |
Hits:
Description: A Comparative Performance Analysis of Four Control
Algorithms for a Three Phase Shunt Active Power Filter Platform: |
Size: 386048 |
Author:yasser |
Hits:
Description: Abstract—In this paper a current reference generation
method for a voltage source shunt active power filter is
examined. The proposed method improves the harmonic
filtering by compensating the delays in the system. In
stationary operating point of the load the method uses
measurement data sampled in previous periods to generate a
reference prediction. Since in transient state of the load the
prediction no longer holds true, a computational control delay
compensation algorithm is used in the reference generation
instead of the prediction in this situation. Changing the
algorithm according to the operating point guarantees effective
harmonic compensation in all operating points. In this paper
the system performance is examined with an active filter
simulation model. Platform: |
Size: 274432 |
Author:yasser |
Hits:
Description: 并联有源电力滤波器(APF)基于空间矢量的滞环控制-Shunt active power filter (APF) based on space vector control hysteresis Platform: |
Size: 1255424 |
Author:zhwb |
Hits:
Description: This work shows the results of applying a shunt active power filter to compensate the harmonic currents generated by a three-phase controlled rectifier full wave, with the load linear circuits (RL). Platform: |
Size: 445440 |
Author:Gleydson |
Hits:
Description: Control of 3-level Shunt Active Power Filter
using Harmonic Selective Controller
Control of 3-level Shunt Active Power Filter
using Harmonic Selective Controller Platform: |
Size: 162816 |
Author:mo |
Hits:
Description: Active shult filter is used to operate grid at unity power factor. Solar panels are used to fed grid as well as load. Platform: |
Size: 24576 |
Author:ShubhamSundeep |
Hits: