Location:
Search - alternator
Search list
Description: 自动化应用--直流电动机和交流发电机控制系统设计,环境为MATLAB-automation applications -- DC motor and alternator control system design environment for MATLAB
Platform: |
Size: 198813 |
Author: 徐政 |
Hits:
Description: 自动化应用--直流电动机和交流发电机控制系统设计,环境为MATLAB-automation applications-- DC motor and alternator control system design environment for MATLAB
Platform: |
Size: 198656 |
Author: 徐政 |
Hits:
Description: 交流发电机电压自动控制器,用于控制交流发电机因外加负载的改变自动稳压之用.-Alternator automatic voltage controller, is used to control alternator load changes due to additional use of automatic voltage regulator.
Platform: |
Size: 2048 |
Author: 吕清宇 |
Hits:
Description: this is a power point for the exciter alternator.
Platform: |
Size: 1139712 |
Author: prathap |
Hits:
Description: A Sensorless Integrated Doubly-Fed Electric Alternator/Active Filter (IDEA) for
Variable Speed Wind Energy System
Platform: |
Size: 377856 |
Author: hocine |
Hits:
Description: 3sfe alternator st190
Platform: |
Size: 118784 |
Author: ksk |
Hits:
Description: ALTERNATOR MATLAB MODEL
Platform: |
Size: 108544 |
Author: loki |
Hits:
Description: 一步交流发电机并网时电力系统暂态故障演示-Step alternator grid power system transient fault demo
Platform: |
Size: 12288 |
Author: 张峰 |
Hits:
Description: Design of a 3 phase round rotor turbo-alternator to satisfy the following specs: 150MW(real power), Y connected, 12.6kV (terminal voltage), 60Hz, 4 pole 0.85 lagging, 250m/s peripheral speed for 20 over speed run, directly cooled stator(water) and rotor(hydrogen), Vfmax = 500V, 60 slots, 14/15 pitch, skew 1 slot, 12 parallel circuits and 25 degree C, working temperature.-Design of a 3 phase round rotor turbo-alternator to satisfy the following specs: 150MW(real power), Y connected, 12.6kV (terminal voltage), 60Hz, 4 pole 0.85 lagging, 250m/s peripheral speed for 20 over speed run, directly cooled stator(water) and rotor(hydrogen), Vfmax = 500V, 60 slots, 14/15 pitch, skew 1 slot, 12 parallel circuits and 25 degree C, working temperature.
Platform: |
Size: 2048 |
Author: Eyisi Paul |
Hits:
Description: :根据内蒙古四子王旗某地2007年逐月平均风速袁选取设计风速为6m/s,根据某型号300 W交流永磁发电机的输出功率特性。利用Matlab编写的叶片优化设计程序,设计了300W水平轴风力发电机叶片。通过风轮与发电机的匹配,调整叶片参数,使之在小风时具有较高的风能利用系数,提高风力机的效率,在大风时具有较低的风能利用系数,从而达到大风时限速保护的目的。-: According to Inner Mongolia as a 2007 monthly average wind speed Yuan select the design wind speed to 6 m/s, according to a Model 300 W output power characteristics of permanent magnet alternator. Leaves written in Matlab to optimize the design process, design 300W horizontal axis wind turbine blades. The wind wheel generator matching adjust the blades parameter, so that has a high wind energy utilization coefficient of small wind, improve the efficiency of the wind turbine in high winds has a lower coefficient of wind energy utilization, so as to achieve high winds speed limit protection purposes.
Platform: |
Size: 152576 |
Author: chentiange |
Hits:
Description: alternator matlab file very good
Platform: |
Size: 2048 |
Author: Marko |
Hits:
Description: alternator project - synchronus machine project
Platform: |
Size: 4096 |
Author: aerton |
Hits:
Description: DTFC-SVM Motion-Sensorless Control of a
PM-Assisted Reluctance Synchronous Machine as
Starter-Alternator for Hybrid Electric Vehicles
Platform: |
Size: 620544 |
Author: Abdelali Walid |
Hits:
Description: 1. A 5 MVA, 10 kV, 1500 rpm, 3 phase, 50 Hz, 4 pole, star connected alternator is operating on infinite bus bars. Determine the synchronizing power per mechanical degree of displacement under no-load condition. Xs = 20 .-1. A 5 MVA, 10 kV, 1500 rpm, 3 phase, 50 Hz, 4 pole, star connected alternator is operating on infinite bus bars. Determine the synchronizing power per mechanical degree of displacement under no-load condition. Xs = 20 .
Platform: |
Size: 12288 |
Author: roshan |
Hits:
Description: 1. A 5 MVA, 10 kV, 1500 rpm, 3 phase, 50 Hz, 4 pole, star connected alternator is operating on infinite bus bars. Determine the synchronizing power per mechanical degree of displacement under no-load condition. Xs = 20 .-1. A 5 MVA, 10 kV, 1500 rpm, 3 phase, 50 Hz, 4 pole, star connected alternator is operating on infinite bus bars. Determine the synchronizing power per mechanical degree of displacement under no-load condition. Xs = 20 .
Platform: |
Size: 660480 |
Author: roshan |
Hits:
Description: direct & quadrature axis reactances of a salient pole alternator.
Platform: |
Size: 23552 |
Author: medo |
Hits:
Description: The dc-ac converter, also known as the inverter, converts dc power to ac power at desired output voltage and frequency. The dc
power input to the inverter is obtained an existing power supply network or a rotating alternator through a rectifier or
a battery, fuel cell, photovoltaic array or magneto hydrodynamic generator.-The dc-ac converter, also known as the inverter, converts dc power to ac power at desired output voltage and frequency. The dc
power input to the inverter is obtained an existing power supply network or a rotating alternator through a rectifier or
a battery, fuel cell, photovoltaic array or magneto hydrodynamic generator.
Platform: |
Size: 509952 |
Author: hung |
Hits:
Description: Phasor diagram of an alternator at lagging power factor is as follows.
Platform: |
Size: 125952 |
Author: mehdimeis
|
Hits: