Description: 红外线遥控器读码软件,显示红外线波型,读取并保存码 IR Remote Control Unit Code Read System 产品详细描述: 能够像显示器一样显示红外线码的波型 可以读多达150种格式的红外线码 显示红外线码的时间非常准确,误差只有几个微秒。 具有错误检测功能 保存红外线码功能 自动识别码的格式 比较样机与所写的新软件的遥控器码的异同 具体情况请访问本网站:http://www.crzman.com/IR_Reader.htm Display the Infrared wave on the software like oscillograph. Can read more than 150 kinds of infrared code format Display the Infrared time and the tolerance no more than many us. Have error detect function Save Infrared code function Auto identify code s format Compare the code from sample and new Remote Control Unit code) Detail instance please visit address: http://www.crzman.com/IR_Reader.htm -infrared remote control code reading software, and display infrared wave, Read and save code IR Remote Control Unit Code Read System Product description : like infra-red monitors showed that the wave-type codes can be read up to 150 infrared codes format shows infrared codes Time is very accurate, error only a few microseconds. Error detection function is to preserve the functional infrared code automatic identification code format compared with the prototype of the new software written by remote control code The similarities and differences between the specific situation, please visit the website : http : / / www.crzman.com / Display the IR_Reader.htm Infrared wave on the software like oscillograp h. Can read more than 150 kinds of infrared code f ormat Display the Infrared time and the t
Platform: | Size: 563567 | Author: 刘友根 | Hits:

[Goverment applicationir_reader37

Description: 红外线遥控器读码软件,显示红外线波型,读取并保存码 IR Remote Control Unit Code Read System 产品详细描述: 能够像显示器一样显示红外线码的波型 可以读多达150种格式的红外线码 显示红外线码的时间非常准确,误差只有几个微秒。 具有错误检测功能 保存红外线码功能 自动识别码的格式 比较样机与所写的新软件的遥控器码的异同 具体情况请访问本网站:http://www.crzman.com/IR_Reader.htm Display the Infrared wave on the software like oscillograph. Can read more than 150 kinds of infrared code format Display the Infrared time and the tolerance no more than many us. Have error detect function Save Infrared code function Auto identify code s format Compare the code from sample and new Remote Control Unit code) Detail instance please visit address: http://www.crzman.com/IR_Reader.htm -infrared remote control code reading software, and display infrared wave, Read and save code IR Remote Control Unit Code Read System Product description : like infra-red monitors showed that the wave-type codes can be read up to 150 infrared codes format shows infrared codes Time is very accurate, error only a few microseconds. Error detection function is to preserve the functional infrared code automatic identification code format compared with the prototype of the new software written by remote control code The similarities and differences between the specific situation, please visit the website : http :// www.crzman.com/Display the IR_Reader.htm Infrared wave on the software like oscillograp h. Can read more than 150 kinds of infrared code f ormat Display the Infrared time and the t
Platform: | Size: 563200 | Author: 刘友根 | Hits:

[Special Effects302

Description: 针对医疗中的心电信号,利用奇异性检测的方法检测R波的位置,并给出模极大曲线-against the medical ECG, the use of the singular method of detection of R-wave detection of the location, and gives modulus maxima curve
Platform: | Size: 1024 | Author: 黄海滨 | Hits:

[matlabecgdetect

Description: 这是用于检测心电信号QRS波的源码用来双正交小波能够实现QRS波形的准确检测-This is used to detect ECG QRS wave source biorthogonal wavelet can be used to achieve accurate detection of QRS waveform
Platform: | Size: 2048 | Author: 白洁 | Hits:

[matlabRjiance

Description: 心电信号QRS波的R波检测,用了阈值的方法,自适应修改阈值,域加窗定位R波幅度-QRS wave of ECG R-wave detection, using a threshold approach, adaptive modification threshold, domain windowed positioning R-wave amplitude
Platform: | Size: 1024 | Author: zhu er | Hits:

[matlabpre_processing

Description: preprocessing of ECG signal for wave detection
Platform: | Size: 2048 | Author: sara | Hits:

[Otherchaoshengboceju

Description: 超声波测距原理 超声波测距是通过不断检测超声波发射后遇到障碍物所反射的回波,从而测出发射和接收回波的时间差t,然后求出距离S=Ct/2,式中的C为超声波波速。 -Ultrasonic Distance Measurement Ultrasonic Distance Measurement principle of continuous detection of ultrasound through the encounter after the launch of the echo reflected from obstacles in order to detect the launch and receive the echo time difference t, and then calculated the distance S = Ct/2, the C-type for the ultrasonic wave velocity.
Platform: | Size: 1024 | Author: 闫石 | Hits:

[OtherECG

Description: 心电信号在线数据知识化辅助诊断算法研究 摘 要:针对心电监护与诊断过程中数据量大、准确性和快速性要求高的特点,提出了一套基于数据知识化的心电 辅助诊断算法.该套算法包括数据识别、冗余处理、转换和提取过程,利用小波变换的多分辨率和抗干扰能力好的 特点,检测QRS波、P波、T波,提高了特征检测的准确性 利用聚类分析具有较好的鲁棒性和适合于大数据量分析 的特点,对QRS进行波形分类 算法结合了单独一搏诊断和串诊断以及多参数综合分析.采用MIT-BIH标准心电 数据库中的部分数据和心电专家确诊的心律失常数据文件对该算法进行了评估,检出率都在95 以上,表明该套 算法对部分心律失常可以进行有效分析. -A series of data knowledge discovery based electrocardiograph (ECG) auxiliary diagnosis algo- rithms were presented against the characteristics of huge data quantum, high accuracy and rapidity de- mands in the ECG monitor and diagnosis process. The algorithm consists of several stages, including data distinguishing, data redundant processing, data conversion and data extraction. The characteristics of wavelet transform, multiresolution and high anti-interference, were used to detect QRS, P and T waves and improve the accuracy of character detection. Clustering analysis characterized by better robustness and capability to analyze huge data quantum was used to classify QRS wave. The algorithm combines diagnosis based on one beat, string diagnosis and comprehensive analysis with multiparameters. Verified by partial data of MIT-BIH standard ECG database and arrhythmia data files diagnosed by ECG experts, the detect- ability exceeded 95 , which showed that the algorithm could analy
Platform: | Size: 68608 | Author: Shi | Hits:

[Special EffectsECGanalysis

Description: ECG信号处理获得各种features,包括P和T波的参数,该程序使用的数据来自mit database 如果要执行该程序,要修改ECG 信号的源文件目录-ECG signal processing to obtain a variety of features, including the P and T-wave parameters, the program uses data from mit database
Platform: | Size: 3828736 | Author: Jun Cheng | Hits:

[matlab97288388MIT-ECG

Description: 心电信号预处理 滤波 去噪 QRs波检测 P波,T波检测-Preprocessing of ECG wave detection filter denoising QRs P wave, T wave detection
Platform: | Size: 3072 | Author: fangdiandian | Hits:

[matlabECG--QRS

Description: 以软件为主的方法实现QRS波的检测滤波之后的信号一般经过一些 变换以提高QRS波的份量,进而采用一系列阈值进行判别,这些阈值有固定 阈值法,也有可变阈值法。前者由于可能的干扰或高P、高T波的存在,若 其滤波后超过其阈值便会产生假阳性(FP,falsepositive)结果;另外,当心 律失常或QRS波幅度变小,阈值设置过高,会导致漏检产生假阴性(FN, falsenegative)结果。由于固定阈值的这些缺点,有研究者提出了用可变阈 值检测,以提高检测的精确率,所采用的可变阈值包括幅度阈值、斜率阈值 和时间间隔阈值等。-Give priority to with software method for detecting QRS wave signal after some commonly after filtering Amount of transformation in order to improve the QRS wave, then using a series of threshold to distinguish, the threshold value is fixed Threshold value method and variable threshold value method. The former due to the possible interference or the existence of the high P and T waves, if More than the threshold value is created after the filtering false positives (FP, falsepositive results In addition, be careful Law of disorder or QRS wave amplitude decreases, threshold is set too high, can lead to leak to produce false negatives (FN, Falsenegative) results. Due to these disadvantages of fixed threshold, some researchers have proposed using variable threshold Value detection, in order to improve the precision of detection rate, adopted by the variable threshold including amplitude threshold, the slope threshold And the time interval threshold, etc.
Platform: | Size: 5120 | Author: 钟能枝 | Hits:

[matlabfind_ecg_point

Description: 心电信号算法,qrs波,t波,检测,检测准确率极高-ECG algorithm, high qrs wave, t wave, detection, detection accuracy
Platform: | Size: 2048 | Author: 徐浩 | Hits:

[ECGDetectFinish

Description: 对心电信号QRS,P,T波检测,有正确率识别以及可靠度较高(QRS, P, and T wave detection of ECG signals, with correct rate identification and high reliability)