Location:
Search - distance relay
Search list
Description: 本文章是关于继电保护方面的论文,涉及到距离保护,利用了全新的比相原理,能够获得理想的效果。-This article is about the Relay papers, related to distance protection, the use of a new phase of more than principle, to obtain the desired results.
Platform: |
Size: 175104 |
Author: 西北偏北 |
Hits:
Description:
Platform: |
Size: 2048 |
Author: Praveen |
Hits:
Description: adaptive distance relay.
in real time programming
Platform: |
Size: 8192 |
Author: nishu |
Hits:
Description: adaptive distance relay.
in real time programming
Platform: |
Size: 1024 |
Author: nishu |
Hits:
Description: In this project we have processed the speech signal with the help of the DIGITAL SIGNAL PROCESSING techniques. The speech signal is given as the input will be verified using speech recognition technique using matlab. We have used Mel Frequency Cepstral Coefficient (MFCC) along with Vector Quantization (VQLBG) and Euclidean Distance to identify different characters. Based on the results, data was send to Parallel Printer Port of the computer & using relay different devices will be controlled.
Platform: |
Size: 2048 |
Author: SimonKap22 |
Hits:
Description: distance relay- finds impedance value of transmission line
Platform: |
Size: 9216 |
Author: manish |
Hits:
Description: 一种基于动态路径损耗指数的最小能耗中继路由 (Dynamic Minimum Energy Relay Routing,DMERR)算法,该算法能够获取巷道内各处准确的路径损耗指数,准确计算巷道内每处的最佳通讯距离,从而节省通信能量。-the Minimum Energy Relay Routing (DMERR) algorithm which is based on dynamic path loss parameter is proposed, this algorithm can save the energy of communication by obtain the exact path loss parameter of each place in roadways and calculation the optimum communication distance accurately.
Platform: |
Size: 9216 |
Author: qiaogz |
Hits:
Description: Remote end infeed causes problems in distance relay measurement, especially under high resistance earth fault conditions. Although a distance relay set to an ideal operating region can cover the fault resistance at one particular load Condition, the operating region is affected by changes in load condition. Hence a distance relay may overreach or underreach when load changes. From the main factors which affect the ideal digital distance relay operating region, a stand alone intelligent digital distance relay which
can adapt to these changes is presented. This approach does not need communication links from the remote end of the line or the system control center. Numerous computer simulations have been
carried out on realistic system configurations and the result9 show that them is a high potential for developing an intelligent digital
distance relay. -Remote end infeed causes problems in distance relay measurement, especially under high resistance earth fault conditions. Although a distance relay set to an ideal operating region can cover the fault resistance at one particular load Condition, the operating region is affected by changes in load condition. Hence a distance relay may overreach or underreach when load changes. From the main factors which affect the ideal digital distance relay operating region, a stand alone intelligent digital distance relay which
can adapt to these changes is presented. This approach does not need communication links from the remote end of the line or the system control center. Numerous computer simulations have been
carried out on realistic system configurations and the result9 show that them is a high potential for developing an intelligent digital
distance relay.
Platform: |
Size: 301056 |
Author: abbas |
Hits:
Description: ATP designer getting started
Platform: |
Size: 30720 |
Author: gaballahkhm |
Hits:
Description: 本文利用编写的MATLAB软件结合解析法证,分析了一种新型的接地距离继电器在系统振荡时再发生单相经过渡电阻接地短路时的动作特性。该接地距离继电器的动作判据是通过比较故障后测得的母线电压、补偿电压、零序电流和负序电流四个量的相位关系以确定继电器的动作行为情况
-In this paper, written in MATLAB software analysis and forensic analysis of a new type of ground distance relays in the system oscillation movement characteristics of single-phase transition resistance is shorted to ground. The operating criteria for the ground distance relay bus voltage is measured by comparing the failure, the phase relationship of offset voltage, zero sequence current and negative sequence current four amount to determine the relay actuation behavior
Platform: |
Size: 4850688 |
Author: nn0914 |
Hits:
Description: 7.1 简单数字滤波器的MATLAB辅助设计和分析方法7.2 微机继电保护算法的MATLAB辅助设计和分析方法7.3 输电线路距离保护的建模与仿真7.4 Simulink在变压器微机继电保护中的应用举例7.5 输电线路故障行波仿真举例
-7.1 Simple digital filter MATLAB-aided design and analysis methods 7.2 microcomputer relay protection algorithm MATLAB-aided design and analysis methods 7.3 Transmission Line Distance Protection 7.4 Simulink modeling and simulation of the transformer relay protection Application Examples 7.5 Transmission Line Examples traveling wave fault simulation
Platform: |
Size: 770048 |
Author: 鱼摆摆 |
Hits:
Description: Numerical Relays Documents
Platform: |
Size: 192512 |
Author: rkcpardis |
Hits:
Description: 包含分布式电源的配电网的距离保护模型,可以直接使用-distance relay protection
Platform: |
Size: 12288 |
Author: 张艳伟 |
Hits:
Description: Distance Relay Protection System
Platform: |
Size: 8192 |
Author: Muhammad |
Hits:
Description: 电力系统中配电网络的距离保护模型,可用于分布式电源并入后的保护方案-Distance protection model power system distribution network can be used for distributed power protection program incorporated
Platform: |
Size: 8192 |
Author: 张艳伟 |
Hits:
Description: this is a simulink file about DistANCE Relay
Platform: |
Size: 16384 |
Author: HAMED |
Hits:
Description: Distance Relay Block 03
Platform: |
Size: 200704 |
Author: AhmadNN
|
Hits:
Description: 22- Distance Relay Block 02
Platform: |
Size: 390144 |
Author: AhmadNN
|
Hits:
Description: 20- Distance Relay Block 00
Platform: |
Size: 2446336 |
Author: AhmadNN
|
Hits:
Description: 21- Distance Relay Block 01
Platform: |
Size: 2537472 |
Author: AhmadNN
|
Hits: