Welcome![Sign In][Sign Up]
Location:
Search - fault isolation

Search list

[Develop Toolsneural-networks

Description: 小波神经网络好文章!A method for fault detection is proposed using a trained neural network as the nominal model of the system to be monitored. Partial physical knowledge, if available, can be combined with the nominal model to perform fault isolation.
Platform: | Size: 369793 | Author: troy | Hits:

[Booksneural-networks

Description: 小波神经网络好文章!A method for fault detection is proposed using a trained neural network as the nominal model of the system to be monitored. Partial physical knowledge, if available, can be combined with the nominal model to perform fault isolation.-WNN good article! A method for fault detection is proposed using a trained neural network as the nominalmodel of the system to be monitored. Partial physical knowledge, if available, can be combinedwith the nominal model to perform fault isolation.
Platform: | Size: 369664 | Author: troy | Hits:

[transportation applicationszuhedaohangguzhangjianceyanjiu

Description: 在组合导航系统工作时,子系统可能会出现某些故障。为了保证导航精度和工作的可靠性,设计的组合导航系统应该具有一定的智能容错能力,即具有故障检测、故障隔离和系统重构功能.-In the integrated navigation system work, there may be some subsystem failures. Navigation in order to guarantee precision and reliability, design of integrated navigation system should have a certain degree of intelligent fault-tolerant capability, which has a fault detection, fault isolation and system reconfiguration functions.
Platform: | Size: 3184640 | Author: 魏蓝 | Hits:

[Otherguzhangzhenduan

Description: 数字电路故障诊断系统,利用二叉树进行故障的分离和识别-Digital circuit fault diagnosis system, the use of binary tree fault isolation and identification
Platform: | Size: 1424384 | Author: 刘永钢 | Hits:

[Mathimatics-Numerical algorithmsfaultAnalysisSys

Description: fault detection and isolation
Platform: | Size: 14336 | Author: badre | Hits:

[Remote ControlPatternsFDI

Description: fault Detection and Isolation with parity -fault Detection and Isolation with parity
Platform: | Size: 239616 | Author: badre | Hits:

[Goverment applicationzhenkongkaiguan

Description: 真空开关柜电动机(6kV带差动保护)开关柜的故障可分成电气绝缘故障和机械故障,故障较多的有以下四种类型:真空开关柜装配的隔离开关支柱绝缘子爬距不够造成的表面闪络短路;-Vacuum switch Motor (6kV with differential protection) of the switch cabinet can be divided into electrical insulation fault failure and mechanical failure, fault more the following four types: vacuum switch assembly of the isolation switch Insulator enough to climb away from the surface caused by flash contact short circuit
Platform: | Size: 645120 | Author: 刘青 | Hits:

[SCMinterturn_DFIG

Description: Abstract— Fault tolerance is gaining growing interest to in-crease the reliability and a vailability of distributed energy sources. Current sensor fault detection,isolation,and reconfiguration are presented for a voltage-oriented controlled doubly fed induction generator, which is mainly used in wind turbines.
Platform: | Size: 784384 | Author: lakhdar | Hits:

[matlabtongjiguochengjianzhi

Description: :在介绍过程监控主要内容及方法的基础上,归纳分析了统计过程监控的发展,详细阐述了传统 的PCA、PCR、PLS、FDA、HMM 和几种改进的PCA方法.指出,将人的经验和专家知识融人到PCA统计过程 监控,提高PCA的故障检测、隔离能力,完善故障诊断与评价能力,将是一个有价值的研究方向-: In the introduction the main content and methods of process monitoring based on the inductive analysis of the statistical process monitoring of development, elaborated on the traditional PCA, PCR, PLS, FDA, HMM, and several improved PCA method. Pointed out that the human experience and financial expertise to the PCA statistical process monitoring of people and improve the PCA fault detection, isolation, and improve fault diagnosis and evaluation capacity, will be a valuable research
Platform: | Size: 238592 | Author: 苏洋 | Hits:

[matlabobs_uio_final

Description: Unknown input observer fault detection and isolation techniques
Platform: | Size: 1024 | Author: Ayyappan | Hits:

[Software EngineeringFault-Detection-and-Isolation-in-Robotic-Manipula

Description: In this work, Artificial Neural Networks are employed in a Fault Detection and Isolation scheme for robotic manipulators. Two networks are utilized: a Multilayer Perceptron is employed to reproduce the manipulator dynamical behavior, generating a residual vector that is classified by a Radial Basis Function Network, giving the fault isolation. Two methods are utilized to choose the radial unit centers in this network. The first method, Forward Selection, employs Subset Selection to choose the radial units from the training patterns. The second employs the Kohonen’s Self-Organizing Map to fix the radial unit centers in more interesting positions. Simulations employing a two link manipulator and the Puma 560 manipulator indicate that the second method gives a smaller generalization error.
Platform: | Size: 149504 | Author: fad | Hits:

[AI-NN-PRmdl_v3.0

Description: 故障检测和隔离.一个个故障检测估计器和一组故障隔离估计器.-A FDI method is developed for wind turbines based on a benchmark system model. A fault detection estimator is used for fault detection, and a bank of fault isolation estimators are employed to determine the particular fault type/location. Each isolation estimator is designed based on a particular fault scenario under consideration.
Platform: | Size: 1280000 | Author: 伍子胥 | Hits:

[matlabTP2SM56

Description: This paper review the effectiveness of the parity space approach to identify faults or disturbance in a system. The most commonly used is the observer based procedures, and redundancy relationship method. This involves analytical mathematical analysis of geometry and bilinear algebra. Then, technological advances which require complex computation such as artificial intelligence and genetic algorithm had made tremendous improvement to fault Detection and Isolation (FDI) analysis. Dynamic Parity Space Approach was studied for a discrete state-space model. Important data will be extracted using this approach especially for residual generation which is the backbones of FDI analysis. Subsequently, at each time instant k, the generated residuals will form a matrix that will define the fault signature. It is remarkable that this approach is proven in this study to be effective in diagnosis and faults isolation.
Platform: | Size: 2606080 | Author: Hazrul | Hits:

[Other Embeded programican

Description: ICAN总线通信原代码,具有自动检测,故障分离,通信速度最高可至1M-ICAN bus communication source code, with automatic detection, fault isolation, communication speed up to 1M
Platform: | Size: 13312 | Author: shirde | Hits:

[AI-NN-PRfault-tolerant-federated-filter

Description: 自适应的动态信息分配方法,联邦滤波的信息分配原则直接影响滤波器的容错性和精度.考虑到故障隔离后的子系统不能参与联邦滤波器的信息分配,首先联邦滤波器的故障检测方法 然后通过引入故障因子,将系统的信息分配和故障状态综合考虑.-The adaptive dynamic information distribution method, the federal filtering the information distribution principles directly affect the fault tolerance and precision of the filter taking into account the subsystem fault isolation can not participate in the allocation of federal filter, the first federal filter fault detection method then through the introduction of a failure factor, considering the information distribution system and the fault status.
Platform: | Size: 3493888 | Author: zkj | Hits:

[matlabica

Description: 自己编写的基于负熵的ICA程序,可以多种实现故障信号的故障分离-I have written based on negative entropy ICA program, a variety of fault isolation can achieve fault signal
Platform: | Size: 3072 | Author: 孟浩 | Hits:

[OtherOn-Line-Process-Monitoring-and-Fault-Isolation-Us

Description: This paper describes a real-time on-line process monitoring and fault isolation approach using PCA (Principal Component Analysis). It also presents the software implementation architecture using an OPC (OLE for Process Control) compliant framework, which enables a seamless integration with the real plant and DCS. The proposed approach and architecture are implemented to monitor a refinery process simulation that produces cyclohexane using benzene and hydrogen. The result shows that both sensor faults and process faults can be detected on-line and the dominating process variables may be isolated.-This paper describes a real-time on-line process monitoring and fault isolation approach using PCA (Principal Component Analysis). It also presents the software implementation architecture using an OPC (OLE for Process Control) compliant framework, which enables a seamless integration with the real plant and DCS. The proposed approach and architecture are implemented to monitor a refinery process simulation that produces cyclohexane using benzene and hydrogen. The result shows that both sensor faults and process faults can be detected on-line and the dominating process variables may be isolated.
Platform: | Size: 257024 | Author: JTNT | Hits:

[Otherprotocol_analysis_003

Description: ICMP协议解码详解,ICMP全称Internet Control Message Protocol,中文名为因特网控制报文协议。它工作在OSI的网络层,向数据通讯中的源主机报告错误。ICMP可以实现故障隔离和故障恢复。-Detailed ICMP protocol decoding, ICMP full name of the Internet Control Message Protocol, the Chinese called the Internet Control Message Protocol. It operates at the network layer of the OSI report errors to the data communication source host. ICMP can achieve fault isolation and fault recovery.
Platform: | Size: 90112 | Author: netlover | Hits:

[transportation applicationsgzjtxbjz

Description: 针对异步电机形成复合故障时电流频谱存在的故障频率成分难以准确分离的问题,结合 小波降噪算法与共振解调技术,提出一种异步电机复合故障分离方法。-For questions asynchronous motors form a complex spectrum of the existence of the fault current is difficult to accurately separate frequency component failure, combined Wavelet Noise Reduction algorithm and resonance demodulation technology, proposes a method of induction motor complex fault isolation.
Platform: | Size: 429056 | Author: lijinhai | Hits:

[OtherPEM

Description: Robust fault diagnosis of proton exchange membrane fuel cells using a Takagi-Sugeno interval observer approach(In this paper, the problem of robust fault diagnosis of proton exchange membrane (PEM) fuel cells is addressed by introducing the Takagi-Sugeno (TS) interval observers that consider uncertainty in a bounded context, adapting TS observers to the so-called interval approach. Design conditions for the TS interval observer based on regional pole placement are also introduced to guarantee the fault detection and isolation (FDI) performance. The fault detection test is based on checking the consistency between the measurements and the output estimations provided by the TS observers. In presence of bounded uncertainty, this check relies on determining if all the measurements lie inside their corresponding estimated interval bounds. When a fault is detected, the measurements that are inconsistent with their corresponding estimations are annotated and a fault isolation procedure is triggered.)
Platform: | Size: 849920 | Author: xifengni | Hits:
« 12 »

CodeBus www.codebus.net