Description: 高次谐波严重危害电网的安全运行,因此必须采取有力措施,使谐波量限制在一定范围内,本文介绍如何在实际工作中提高滤波器的质量-high harmonics seriously endanger the safe operation of power grids, it is necessary to take effective measures, Harmonic so limited in a certain range, the paper how in practical work to improve the quality filter Platform: |
Size: 322946 |
Author:12313 |
Hits:
Description: 高次谐波严重危害电网的安全运行,因此必须采取有力措施,使谐波量限制在一定范围内,本文介绍如何在实际工作中提高滤波器的质量-high harmonics seriously endanger the safe operation of power grids, it is necessary to take effective measures, Harmonic so limited in a certain range, the paper how in practical work to improve the quality filter Platform: |
Size: 322560 |
Author:12313 |
Hits:
Description: 自适应滤波器程序,选用电力系统谐波信号作为输入。其中包括了wiener滤波器,kalman滤波器,LMS算法,RLS算法,LSL算法,FTF算法。所有程序均为本人自编,并且标注了编程所参考的书籍及页数,经过调试,完全正确,请放心使用。-Adaptive filter procedures, selection of power system harmonics signal as input. Including the wiener filter, kalman filter, LMS algorithm, RLS algorithm, LSL algorithm, FTF algorithm. All Programs are my own, and marked by a programming reference books and pages, after debugging, completely correct, please rest assured that use. Platform: |
Size: 3072 |
Author:李明 |
Hits:
Description: CZT和FFT的C语言实现代码,能有效滤除谐波,噪声。获得信号的频率,是一种良好的频率测量算法。-CZT and FFT of the C language code, can effectively filter out harmonics and noise. Access to the signal frequency, is a good algorithm for frequency measurement. Platform: |
Size: 1024 |
Author:zhujia |
Hits:
Description: 一阶低通滤波函数,能很好的消弱高次谐波或频率较高的干扰和噪声!-First-order low-pass filter function that can weaken a very good high harmonics or high frequency interference and noise! Platform: |
Size: 1024 |
Author:姜评 |
Hits:
Description: SIMULINK的仿真图,用于电力系统谐波抑止的,有些环境可能不兼容。-SIMULINK simulation diagram for power system harmonics curbed, and some may not be compatible with the environment. Platform: |
Size: 13312 |
Author:ian |
Hits:
Description: 针对混沌参数调制( C P M) 的电力线通信( P L C) 中谐波引起的窄带干扰, 两阶段动态估计方法根据最小
相空间体积( MP S V) 准则估计模型参数, 计算量大。为此, 提出将未知参数合并到增广状态矩阵的联合卡尔曼滤
波方法, 避免了专门的参数估计过程, 在提高增益性能的同时有效降低了计算量。方法的性能通过对混沌电力
线通信下的单音干扰和多音干扰的有效抑制得到了验证。-For the chaotic parameter modulation (CPM) of the power line communication (PLC) in the narrow-band interference caused by harmonics, two-phase dynamic estimation methods with minimum phase space volume (MP SV) criterion estimate model parameters, calculation of volume. Toward this end, the unknown parameters into augmented state matrix of the joint Kalman filter, to avoid the special parameter estimation process, while improving the performance gain reduces the amount of calculation. Method of performance under the power line communication by chaotic multitone jamming tone interference and the effective suppression has been verified. Platform: |
Size: 272384 |
Author:张海洋 |
Hits:
Description: 用matlab语言实现陷波器,达到消除指定频率的谐波的功能-Language with matlab notch filter, to eliminate the function of the specified frequency harmonics Platform: |
Size: 1024 |
Author:yutingliu |
Hits:
Description: simulink系统仿真:10kV 母线短路容量为10MVA,通过额定电压10/0.4kV,额定容量为100kVA,短路阻抗为5%的变压器与负荷相连, 阻感负荷RL 容量为50kVA,功率因数0.9。电力电子装置产生的5 次和7 次谐波电流均为5A;为了抑制7 次谐波在400V 母线处接入电容与变压器构成7 次滤波器。-simulink System Simulation: 10kV busbar short-circuit capacity of 10MVA, through the rated voltage 10/0.4kV, the rated capacity of 100kVA, short-circuit impedance of 5 of the transformer and load connected to sense the load resistance RL capacity 50kVA, power factor of 0.9. Generated by power electronic devices 5 and 7 harmonic currents are 5A to suppress harmonics in the 400V bus 7 access to capacitors and transformers constitute at 7 filter. Platform: |
Size: 10240 |
Author:othanda |
Hits:
Description: Fuzzy Logic Controller Based Three-phase Shunt Active Filter for Line Harmonics Reduction using matlab simulation Platform: |
Size: 1217536 |
Author:akhi |
Hits:
Description: 并联有源电力滤波器(APF)基于空间矢量的滞环控制-Shunt active power filter (APF) based on space vector control hysteresis Platform: |
Size: 1255424 |
Author:zhwb |
Hits:
Description: In higher power applications to utilize the full line power and reduce line current harmonics PFC
Pre-regulators are generally required. In these high power applications interleaving PFC stages can
reduce inductor volume and reduce input and output capacitor ripple current. This results in smaller overall
magnetic volume and filter capacitor volume increasing the converters overall power density. This is made
possible through distributing the power over two interleaved boost converters and the inductor ripple
current cancellation that occurs with interleaving, reference [5]. This application note will review the design
of a 300W two-phase interleaved power factor corrected (PFC) pre-regulator. T Platform: |
Size: 771072 |
Author:venkatesh |
Hits:
Description: PECTRUM of the input current drawn by the electric
drive from the network is affected by the used type of the
input rectifier. In the case of the diode rectifier, the number of
its pulses is decisive. Standard AC adjustable speed drives
utilize the input three phase six-pulse diode rectifier for the
AC-DC conversion. These drives generate harmonics into the
network, so the drawn current is not harmonic, but nonharmonic
with a high level of distortion if no harmonic filter
is used. The input current total harmonic distortion is
calculated from the formula Platform: |
Size: 732160 |
Author:imedp |
Hits:
Description: this gives you detailed abt the active power filter and its used. You can mitigates the harmonics by using a active power filter. Platform: |
Size: 434176 |
Author:amit |
Hits:
Description: this gives you detailed abt the active power filter and its used. You can mitigates the harmonics by using a active power filter. Platform: |
Size: 487424 |
Author:amit |
Hits:
Description: In this paper, an efficient active power filter (APF) scheme is developed to estimate and compensate for harmonic distortion in an electrical power network. The developed APF control scheme is based on a double proportional feedback controller and a single-phase voltage-source half-wave bridge inverter. The proposed filter uses a Multi-layer Artificial Neural Network (MLANN) with a shift method for estimating system harmonic currents and voltages at a dedicated point. The proposed scheme is tested on a 13 bus industrial distribution system. The obtained results ensure the effectiveness of the proposed filter. The system is simulated in MATLAB-Simulink and simulation results prove that the polluting harmonics have been greatly reduced. Platform: |
Size: 1906688 |
Author:amir1 |
Hits:
Description: 模糊逻辑控制器的谐波最小化。出现了给用户提供优质电能的问题。这是由于网络中非线性负载的增加,构成了电网的谐波污染源,产生了许多干扰,干扰了电气设备的优化运行。本文提出了消除非线性负载引入的谐波的解决方案。利用Matlab Simulink对有源电力滤波器(APF)在稳态和暂态过程中对非线性负载产生的谐波和无功功率进行了补偿和分析。仿真方法对有源电力滤波器的实用性得到了证明,利用MATLAB SIMULINK具有更好的电能质量洞察力,以开发基于有源电力滤波器的新型模糊逻辑控制器(This is due to the increasing presence in network of nonlinear loads.They constitute a harmonic pollution source of the network, which generate many disturbances, and disturb the optimal operation of electrical equipments. This work, proposed a solution to eliminate the harmonics introduced by the nonlinear loads. It presents the analysis and simulation using Matlab Simulink of a active power filter (APF) compensating the harmonics and reactive power created by nonlinear loads in steady and in transients. The usefulness of the simulation approach to APF is demonstrated , have a better power quality insight using Matlab Simulink in order to develop new fuzzy logic controller based active power filte) Platform: |
Size: 405504 |
Author:阿飞之父 |
Hits: