Description: 利用相关算法检测微弱信号的一个方法,适合于分析心律或者呼吸频率等生物信号-related to the use of weak signal detection algorithm in a way suited to analysis of heart rate or respiratory frequency signal biological Platform: |
Size: 327680 |
Author:王书军 |
Hits:
Description: 这是基于PIC系列单片机的C语言编程,采用阈值法检测QRS波,并且将检测到的QRS波经过高低通滤波、微分、移动窗口积分后,通过检测两个相邻的峰值,计算出心率-This is based on the PIC series MCU C language programming, using the threshold detection QRS wave, and the QRS wave is detected after a low pass filter, differential, mobile window points to the public through the detection of two adjacent peaks, calculate the heart rate Platform: |
Size: 5120 |
Author:李培 |
Hits:
Description: This application report discusses the design of non-invasive optical plethysmography
also called as pulsoximeter using the MSP430FG437 Microcontroller (MCU). The
pulsoximeter consists of a peripheral probe combined with the MCU displaying the
oxygen saturation and pulse rate on a LCD glass. The same sensor is used for both
heart-rate detection and pulsoximetering in this application. The probe is placed on a
peripheral point of the body such as a finger tip, ear lobe or the nose. The probe
includes two light emitting diodes (LEDs), one in the visible red spectrum (660nm) and
the other in the infrared spectrum (940nm). The percentage of oxygen in the body is
worked by measuring the intensity from each frequency of light after it transmits
through the body and then calculating the ratio between these two intensities. Platform: |
Size: 1603584 |
Author:guyanzu |
Hits:
Description: 检测心率并在1602液晶上显示,当心率超过一定数字,蜂鸣器自动报警-Detection of heart rate displayed on the LCD in 1602, when the heart rate exceeds a certain figure, buzzer alarm Platform: |
Size: 1856512 |
Author:Tuliang |
Hits:
Description: 心电图峰值提取算法,可用来处理心电数据并计算心率并判断心律正常与否
-ECG peak extraction algorithm can be used to handle ECG data and calculate the heart rate and rhythm is normal or not judged Platform: |
Size: 96256 |
Author:冯足平 |
Hits:
Description: 基于界面操作的人脸心率检测的代码,通过摄像头实时采集人视频,并计算心率-Face the heart rate detection interface operation based on the code, through real-time acquisition one camera video, and rate Platform: |
Size: 17408 |
Author:wwwmmm |
Hits:
Description: Android Java 通过蓝牙接受数据,画出无线心电图 -ECG analysis software, including a QRS detector algorithm. The algorithm here, designed to detect the QRS complexes in the electrocardiogram using by Pan J and Tompkins WJ. A Real-Time QRS Detection Algorithm. Platform: |
Size: 159744 |
Author:chen |
Hits:
Description: 主要描述PPG进行心率检测的文档,描述了具体的一些心率的检测算法及相关的算法评定。-PPG describes heart rate testing documentation, describing some of the specific heart rate detection algorithm and related algorithms assessment. Platform: |
Size: 1652736 |
Author:徐平 |
Hits:
Description: 基于可见光成像设备抑制运动伪差的脉搏波及心率检测技术研究,研究和比较了多种运动伪像算法,从而保证能够获取更好更准确的分析。-Based visible imaging device motion artifact suppression pulse spread heart rate detection technology research, study and compare a wide range of motion artifacts algorithm, thus ensuring better able to get a more accurate analysis. Platform: |
Size: 3254272 |
Author:徐平 |
Hits:
Description: heart rate produced by algorithms embedded in the commercially
available optical heart rate sensor. An analysis of the raw PPG signal is
necessary to fully assess the usability of PPG for heart rate detection in
epilepsy, for instance, by also including measures for heart rate variability.
Mean heart rate is a suitable measure to detect tachycardia,
bradycardia, and asystole, which are importantmarkers of clinical relevance
of seizures. However, in other medical settings, such as the uation
of arrhythmias [10], more features of heart rate and ECG
characteristics such as QT interval,which PPG currently cannot provide,
are necessary for proper monitoring. Measurements in other patient
groups are necessary-heart rate produced by algorithms embedded in the commercially
available optical heart rate sensor. An analysis of the raw PPG signal is
necessary to fully assess the usability of PPG for heart rate detection in
epilepsy, for instance, by also including measures for heart rate variability.
Mean heart rate is a suitable measure to detect tachycardia,
bradycardia, and asystole, which are importantmarkers of clinical relevance
of seizures. However, in other medical settings, such as the uation
of arrhythmias [10], more features of heart rate and ECG
characteristics such as QT interval,which PPG currently cannot provide,
are necessary for proper monitoring. Measurements in other patient
groups are necessary Platform: |
Size: 128000 |
Author:senthil |
Hits:
Description: 血氧饱和度与心率传感器max30102代码,该代码可用于检测温度,可在该代码上设计血氧饱和度与心率检测的代码。-Oxygen saturation with the heart rate sensor max30102 code, which can be used to detect the temperature at which the code can be designed for oxygen saturation and heart rate detection. Platform: |
Size: 5664768 |
Author:张蓉欢 |
Hits: