Welcome![Sign In][Sign Up]
Location:
Search - low-voltage grid

Search list

[Algorithmcaoliu

Description: PQ分解法潮流计算程序。既可以用于高压输电网的潮流解算,又可以用于低压配电网的潮流解算,还可以同时解算输电网 加配电网的混合潮流问题。-PQ decomposition process flow calculation. Both high-voltage transmission networks can be used to calculate the trend, but also can be used in the trend of low voltage distribution network solver, but also at the same time increase the supply grid solver distribution network issues mixed trend.
Platform: | Size: 8192 | Author: coco | Hits:

[Other systemspf30

Description: 潮流计算源程序。 既可以用于高压输电网的潮流解算,又可以用于低压配电网的潮流解算,还可以同时解算输电网加配电网的混合潮流问题。 -Source flow calculation. Both high-voltage transmission networks can be used to calculate the trend, but also can be used in the trend of low voltage distribution network solver, but also at the same time increase the supply grid solver distribution network issues mixed trend.
Platform: | Size: 13312 | Author: solomon | Hits:

[OtherDynamicmodelsimulationofdoubly-fedwindturbines

Description: 为满足在电网发生故障时风电机组需保持与电网连接并向系统不间断供电的要求,提出 了双馈风力发电机的动态模型、变流器模型、变流器保护及电网模型,以研究双馈风力发电机的暂 态特性.以1·5MW SUT-1500双馈风力发电机为原型,由一个无穷大电源等效电网模型,变流器模 型采用定子磁链的定向电流矢量控制方法,利用PSCAD软件对双馈电机的暂态特性进行仿真.仿 真结果表明,矢量控制能够实现双馈电机的有功、无功解耦,并可改善系统的低压穿越能力. -To meet the power failure to keep their wind turbine grid-connected uninterruptible power supply to the system requirements, proposed doubly-fed wind turbine dynamic models of converter model, inverter protection and network model to Study of double-fed wind generator transient characteristics. to 1.5 MW SUT-1500 double-fed wind turbine prototypes, by an infinite power grid equivalent model of converter model uses the stator flux orientation of current vector control methods, using PSCAD software to double-fed motor simulation of transient characteristics. The simulation results show that vector control can be achieved double-fed motor active and reactive decoupling, and can improve the system through the capacity of low-voltage.
Platform: | Size: 619520 | Author: mengxianghua | Hits:

[Program dochubei

Description: 国家电网湖北省低压电力集抄集中器上行的通讯规约-National Grid set of Hubei Province, low-voltage power concentrator upstream copy of the communication protocol
Platform: | Size: 494592 | Author: 李宗桦 | Hits:

[Program docjicao

Description: 国家电网湖北省电力公司低压电力集抄系统技术条件-National Grid Hubei Electric Power Company low voltage electrical systems and technical conditions set copy
Platform: | Size: 200704 | Author: 李宗桦 | Hits:

[Communication-Mobiledas

Description: Demodulating the signal. DeAmpMod = (1/2).*(ademod(AmpMod,Fc,Fs, amdsb-sc ,num,den)) (ALTERNATIVE APPROACH) DeAmpMod = AmpMod.*Cs Designing butterworth low pass filter. [num,den] = butter(2,.8) FilteredOutput = filter(num,den,DeAmpMod) Plotting the input speech signal data . subplot(2,2,1) axis normal plot(data) grid on title( Initial Speech Signal ) xlabel( Samples ) ylabel( Speech Signal ) Plotting the modulated speech signal AmpMod . subplot(2,2,2) axis normal plot(AmpMod) title( Modulated Speech Signal ) xlabel( Samples ) ylabel( Modulated Signal )- Demodulating the signal. DeAmpMod = (1/2).*(ademod(AmpMod,Fc,Fs, amdsb-sc ,num,den)) (ALTERNATIVE APPROACH) DeAmpMod = AmpMod.*Cs Designing butterworth low pass filter. [num,den] = butter(2,.8) FilteredOutput = filter(num,den,DeAmpMod) Plotting the input speech signal data . subplot(2,2,1) axis normal plot(data) grid on title( Initial Speech Signal ) xlabel( Samples ) ylabel( Speech Signal ) Plotting the modulated speech signal AmpMod . subplot(2,2,2) axis normal plot(AmpMod) title( Modulated Speech Signal ) xlabel( Samples ) ylabel( Modulated Signal )
Platform: | Size: 1024 | Author: dasu | Hits:

[matlabb21

Description: Taking into account all the parameters mentioned, forming the appropriate programming to the controller in order to achieve the synchronization between the two systems, the appropriate amplitude and as well as the power management to the DC to control the power that is injected to the electrical grid, the results we take are in the range of high performance inverters. In this simulation scenario the power is high as the current has been increased and the THD is low
Platform: | Size: 305152 | Author: mimo | Hits:

[OtherTUV

Description: TUV认证标准,400V 以下低压并网光伏发电专用逆变器技术要求和试验方法.-TUV certification standards, 400V power in low voltage grid-connected photovoltaic inverter specific technical requirements and test methods.
Platform: | Size: 315392 | Author: husuhua | Hits:

[OtherAS_4777.1-2005

Description: AS4777资料,关于光伏逆变器方面的,,400V 以下低压并网光伏发电专用逆变器技术要求和试验方法,-AS4777, information on aspects of PV inverters,, 400V power in low voltage grid-connected photovoltaic inverter technology-specific requirements and test methods
Platform: | Size: 357376 | Author: ylmf246735 | Hits:

[matlabpsa

Description: 既可以用于高压输电网的潮流解算,又可以用于低压配电网的潮流解算,还可以同时解算输电网 加配电网的混合潮流问题,程序为PQ 分解法.-Both the trend for high-voltage transmission grid solver, but also the trend for low voltage distribution network solver, solver can also increase with the power transmission grid hybrid power flow problem, the program for the PQ decomposition.
Platform: | Size: 66560 | Author: andy.qian | Hits:

[Otherlzh(20100613)

Description: 电力系统的低压电网中,通过输入部分关键数据,例如导线长度,电网中节点数等,达到计算低压电网线损的一个简单小程序-Low-voltage power grid power system, by entering some key data, such as wire length, the grid nodes, etc., to calculate the low-voltage power line loss is a simple applet
Platform: | Size: 2048 | Author: 李争辉 | Hits:

[Industry researchDFIG

Description: 关于DFIG的低压穿越能力的研究。对以后实现低压穿越做一些探索性的工作-Along with the sharp increase in the proportion of wind power supply some areas the impact of Large-scale wind farms for the stability of regional power grid is more significant. The research on low voltage ride-through (LVRT) of wind power system based on doubly-fed induction generators (DFIG) becomes a hot issue. In this paper ,Firstly introduces the concept of low voltage ride-through technology, The standards of LVRT of some European countries are presented, And then analyses and compares the kinds of common realize low voltage ride- technology and improve control strategy. The transient characteristics of DFIG when the grid voltage sagging.
Platform: | Size: 327680 | Author: 韩萌 | Hits:

[Mathimatics-Numerical algorithms9klmn4.ZIP

Description: 电网对称故障时双馈感应发电机低电压穿越控制Symmetrical grid fault of doubly fed induction generator low voltage ride-through control-Symmetrical grid fault of doubly fed induction generator low voltage ride-through control
Platform: | Size: 1607680 | Author: kk22 | Hits:

[matlabLowVoltageMicroGride

Description: 基于simulink的西门子标准400V低压馈线模型,其中包含一个PV光伏并网模型-Based on the the simulink Siemens standard 400V low voltage feeder model, which contains a PV photovoltaic grid model
Platform: | Size: 23552 | Author: 毛盛龙 | Hits:

[Technology Management4

Description: 对广大供电企业来说,用户功率因数的高低,直接关系到电力网中的功率损耗和电能损耗,关系到供电线路的电压损失和电压波动,而且关系到节约电能和整个供电区域的供电质量,这是众所周知的道理。提高电力系统的功率因数,已成为电力工业中一个重要课题。文中简要集中探讨了影响电网功率因数的主要因素以及低压无功补偿的几种实用方法,和确定无功补偿容量从而提高电力系统功率因数的一般方法。-For the majority of power supply enterprises, the level of user power factor, is directly related to the power loss and power loss in the power grid, related to the voltage of the power supply line losses and voltage fluctuations, but also to save energy and supply area for electric quality, this is a well-known truth. Improve the power factor of the power system, the power industry has become an important topic. Briefly several practical approach focuses on the main factors affecting the grid power factor and low voltage reactive compensation, and determine the reactive power compensation capacity of the general method to improve the power factor of power system.
Platform: | Size: 11264 | Author: dxw | Hits:

[Other05953525

Description: 双馈电机如何通过低压的过程,很好的外文文献,很好的控制策略-An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults
Platform: | Size: 1222656 | Author: baohecusos | Hits:

[Othery

Description: 一种便携式低压电网数据采样与分析系统的研制-杨杰-A portable low-voltage power grid data sampling and analysis system developed- Yang Jie
Platform: | Size: 484352 | Author: Le | Hits:

[Software EngineeringWind

Description: a new circuit topology of a phase-locked loop that can be used for synchronising a singlephase wind turbine generator (WTG) with the low voltage utility grid. The circuit is based on the time-delay digital tanlock loop (TDTL) architecture and was modelled and simulated using Simulink/MATLAB. The results presented demonstrate the ability of the circuit not only to synchronise a WTG with the grid, but also to re-gain synchronization following a sudden disturbance in the grid voltage. The simulated disturbances included a ramp and a multi-step change in the phase of the grid voltage waveform.
Platform: | Size: 16384 | Author: Amr | Hits:

[matlabPRI

Description: In this paper, a simple single-phase grid connected photovoltaic (PV) inverter topology consisting of a boost section, a low-voltage single-phase inverter with an inductive filter, and a step-up transformer interfacing the grid is considered. Ideally, this topology will not inject any lower order harmonics into the grid due to high-frequency pulse width modulation operation. However, the nonideal factors in the system such as core saturation-induced distorted magnetizing current of the transformer and the dead time of the inverter, etc., contribute to a significant amount of lower order harmonics in the grid current. A novel design of inverter current control that mitigates lower order harmonics is presented in this paper.
Platform: | Size: 18432 | Author: hareesh | Hits:

[Software EngineeringA-Genetic-Algorithm-Based-Low-Voltage

Description: A Genetic Algorithm-Based Low Voltage Ride-Through Control Strategy for Grid Connected Doubly Fed Induction Wind Generators
Platform: | Size: 1770496 | Author: hakkeem | Hits:
« 12 3 »

CodeBus www.codebus.net