Description: ORCAD编写的准谐振变流器仿真程序,可以观察MOS管导通过程-ORCAD prepared by the quasi-resonant converter simulation, we can observe the MOSFET conduction process Platform: |
Size: 38842 |
Author:新美 |
Hits:
Description: ORCAD编写的准谐振变流器仿真程序,可以观察MOS管导通过程-ORCAD prepared by the quasi-resonant converter simulation, we can observe the MOSFET conduction process Platform: |
Size: 38912 |
Author:新美 |
Hits:
Description: 准谐振变流器matlab/simulink仿真程序,观察模型特性-quasi-resonant converter Matlab/Simulink simulation program to observe the model characteristics Platform: |
Size: 6144 |
Author:新美 |
Hits:
Description: LLC变换器的数字控制思想,基于C语言的算法。-A novel over-current protection method for LLC
resonant converter has been proposed in this paper. This method
is very attractive for its good current limit ability, especially
under short circuit condition. Moreover, its current limit point
range is easy to be optimized. Detailed theoretical analysis and
optimization design considerations have been presented. An
experimental prototype converter based on the proposed method
was built up to verify the theoretical analysis Platform: |
Size: 1317888 |
Author:称自己 |
Hits:
Description: LLC型串并联谐振变换器参数分析与运用。还要我说什么的,就是这么点-LLC-type series-parallel resonant converter parameter analysis and application. What should I say, that is such a point Platform: |
Size: 982016 |
Author:rfish |
Hits:
Description: This paper presents the analysis and design of a
new ac-ac resonant converter applied to domestic induction
heating. The proposed topology, based on the half-bridge series
resonant inverter, uses only two diodes to rectify the mains
voltage. The proposed converter can operate with zero voltage
switching during both switch-on and switch-off transitions.
Moreover, this topology doubles the output voltage and,
therefore, the current in the load is reduced for the same output
power. As a consequence, the converter efficiency is significantly
improved.
The analytical and simulation results have Platform: |
Size: 922624 |
Author:sajitsanit |
Hits:
Description: Finally it is observed that by using this filter, the common mode noise level of 2MHz resonant converter is suppressed according to CISPR 22 standard limits Platform: |
Size: 31744 |
Author:suga |
Hits:
Description: converter is suppressed according to CISPR 22 standard limits. The fundamental frequency component with higher order harmonics of 2 MHz resonant converter after the application of filter is at 33.18 dBµ V. The designed filter has attenuated the common mode conducted noise by 140 dBµ V. Platform: |
Size: 20480 |
Author:suga |
Hits: