Description: System startup, minus 1 "plus a button, button, confirmation button" to set the upper limit and lower limit of the temperature. After the completion of digital tube displays the current temperature in real time. When the temperature below the lower limit temperature, the 1st LED and buzzer continued to a frequency of sound and light alarm 2 LEDs and buzzer when the temperature is higher than the upper limit temperature, continues to another frequency sound and light alarm. Provide circuit.