Description: Process input is driven by the M sequence, i.e., u (k) is an M sequence. Process transfer function G (s) K = 120, T1 = 8.3Sec T2 = 6.2Sec. The impulse response of the process of the theoretical value of g (k) meet. According to the process input and output data u (k) and z (k), the use of correlation analysis algorithm to estimate the impulse response of a process value g2 (k).