Description: At SRRC, a precision output current monitoring
system is installed to monitor the output performance of
all the booster/storage ring power supplies. Accurate DC
current transformers (DCCTs) are attached to the output
terminal of every power supply system. Each
transformer s gain/offset are carefully calibrated against
high precision current source and approximated using
high-order polynomial curve fitting. The output of each
DCCT is connected to multi-channels data logger for realtime
data collection, the collected data are calibrated
using the interpolated DCCT gain/offset value. A PC
station is set up to serve as host to store the current output
for real-time monitoring. This monitoring system provide
a precise real-time database for rapid fault diagnosing
whenever there is malfunction of the beam operation
- [polyfit] - polynomial curve fitting procedures corr
- [taylor] - Animation for 1. Polynomial fitting 2.
File list (Check if you may need any files):
1970fb.pdf