Description: With local parameter optimization method to design a model reference adaptive system, adjustable gain initial Kc (0) = 0.2, for a given value of r (t) for the unit step signal that r (t) = A × 1 ( t). Requirements: a continuous system discretization (sampling time of 0.1 preferred). 2 compiled and run the system computer program (Note B to adjust the value of the system to obtain better adaptive characteristics). 3 records ym, yp curve record kp × kc curve records generalized output error e curves. 4 parameter convergence, let Kp = 2 into the Kp = 1, re-observed Kp × Kc and e curves. B-5 to find value in determining the next, making the system unstable A value (step signal of amplitude), and using Routh stability criterion and the comparison of the results calculated.
To Search:
- [AdaptiveControl] - This document is my adaptive control lar
- [selfadapting3] - Another solution to the issue of model-f
- [aug_routh] - Augmented Routh table Calculation. AUG_R
- [popov1] - popov
- [zsykz] - Beijing Institute of Technology graduate
- [Routh] - Routh houritz citeria development
File list (Check if you may need any files):
pro_2.m