Welcome![Sign In][Sign Up]
Location:
Search - Stability of wind farm

Search list

[ARM-PowerPC-ColdFire-MIPSResearch_on_Wind_Farm_Modeling

Description: 本文对风电场—无穷大系统进行了简单的仿真分析,主要包括小干扰稳定分析,风电场的并网、负荷扰动以及联络线故障时的暂态分析。然后以达里风电场所在系统为例,在稳态分析和暂态分析的基础上计算风电场允许接入最大容量。 -In this paper, Wind Farm- infinite simple system simulation analysis, including small signal stability analysis, wind farm and the net tie-line load disturbances, as well as the failure of the transient analysis. And then wind up in the host system as an example, in the steady-state analysis and transient analysis based on the calculation of the largest wind power capacity to allow access.
Platform: | Size: 1116160 | Author: Eason.Yuan | Hits:

[File FormatResearch

Description: 风电场的暂态仿真,利用matlab建模仿真,研究暂态性能-Research on Improving Transient Voltage Stability of Wind Farm by STATCOM
Platform: | Size: 71680 | Author: 黄建涛 | Hits:

[Otherf.Dynamic-Analysis-of-Onshore-Offshore-WT

Description: DYNAMIC STABILITY ANALYSIS OF ONSHORE AND OFFSHORE WIND FARM CONNECTED TO THE GRID
Platform: | Size: 968704 | Author: ram | Hits:

[OtherDYNAMIC-STABILITY-ENHANCEMENT-OF-A-PLANNED

Description: DYNAMIC STABILITY ENHANCEMENT OF A PLANNED WIND FARM WITH A STATIC VAR COMPENSATOR
Platform: | Size: 899072 | Author: jyotsna | Hits:

[File FormatControl_of_a_Multilevel_Converter_for_Power_Quali

Description: High penetration of wind energy into the grid may introduce stability and power quality problems due to the fluctuating nature of the wind and the increasing complexity of the power system. By implementing advanced functionalities in power converters, it is possible to improve the performance of the wind farm and also to provide grid support, as it is required by the grid codes. One of the main compliance difficulties that can be found in such power plants are related to reactive power compensation and to keep the harmonics content within the allowed limits, even if the power of the WPP converters is increasing. This paper deals with an advanced control strategy design of a three-level converter performing STATCOM and Active Filter functionalities. A novel control strategy called Smart-STATCOM is introduced, since it has the capability of self-controlling reactive power and harmonic voltages at the same time.
Platform: | Size: 3078144 | Author: hocine | Hits:

[Software EngineeringCase-studies

Description: 风电场建模的案例分析。资料中详细分析了风电场建模的方法,并着重考虑了短路电流、LVRT、稳定性分析等内容。- Using an actual wind farm configuration, this paper compares the effects of modeling detail on power flow calculations such as those used to determine reactive power requirements, voltage control strategy, wind farm losses, and external events such as contingencies on the bulk power system, calculations of short circuit currents, and stability analysis including transient stability, low voltage ride through (LVRT), and wind farm oscillations.
Platform: | Size: 1122304 | Author: Blogflyer | Hits:

[OtherDC-ransmission

Description: 多端直流输电系统(multi-terminal DC,MTDC)为解决 大型风电基地功率外送的瓶颈问题提供了一个最佳解决方 案。研究了基于电压源换流器(voltage source converter,VSC) 的多端直流输电系统应用于大规模风电功率长距离外送时 的协调控制策略。通过构建一个四端系统连接两个大型风电 基地及本地电网向远方负荷中心进行功率输送,实现了风电 场的功率汇集和外送。仿真验证了该协调控制策略在大扰动 情况下,不仅能够提高VSC-MTDC系统潮流重新分配的能 力,而且可使风电场对直流网络提供一定功率支撑,增强了 电力系统动态稳定性 -Multi-terminal DC (MTDC) power transmission system is regarded as the optimal solution scheme to sent out power from large-scale wind farm. A coordinated control strategy for voltage source converter (VSC) based MTDC transmission system applied to long-distance power transmission from large-scale wind farm is researched. By means of constructing a four-terminal system connecting two large-scale wind power bases with local power grid to send out power to faraway load center, the wind power converging and sending out by the proposed coordinated control strategy are implemented. Simulation results show that the proposed coordinated control strategy not only can improve the ability of reallocating power flow in VSC-MTDC transmission system under large disturbance, but also can make wind power base providing a certain power support to DC transmission network, thus the dynamic stability of power grid can be enhanced.
Platform: | Size: 645120 | Author: chenchen | Hits:

[Otherwind

Description: 基于矢量解耦控制策略,建立了适用于电力系统暂态 稳定分析的直驱式风力发电机组机电暂态模型。为模型做了 2点合理假设:有功功率和无功功率在暂态过程中完全解耦; 测量的电气量准确,和实际的电气量完全相等。基于这些条 件,从实际的物理装置出发,对直驱式风电机组的电磁暂态 模型进行简化。考虑了变频器直流电压的动态过程和低电压 穿越的运行特性。仿真结果表明,该模型和电磁暂态模型动 态响应曲线一致,结果准确、可靠,可以用于分析大规模直 驱式风电场接入对电力系统安全稳定性的影响-Based on vector decoupling control strategy is suitable for power system transient is established Stability analysis of direct drive wind turbine electromechanical transient model. For the model to do 2 some reasonable assumption: active power and reactive power in the transient process of the decoupling completely The accurate measurement of electric parameters, and fully equal to the actual electric parameters. On the basis of these article , starting from the actual physical device, electromagnetic transient of direct drive wind turbines To simplify the model. Considering the dynamic process of dc voltage and the frequency converter low voltage Through the operation of the features. The simulation results show that the model and the electromagnetic transient model Transient response curve is consistent, accurate, reliable and can be used for analysis of large-scale straight The displacement type wind farm access impact on the stability of power system security
Platform: | Size: 969728 | Author: 孟侠 | Hits:

[Software Engineeringwind-power-on-stability-control-

Description: 很详细的一篇研究双馈风力发电 风速扰动、风电场出口故障、系统线路故障三种状态下对电力系统的影响,且通过MATLAB仿真验证。-A very detailed study of the doubly-fed wind power wind disturbances affecting the wind farm exports fault line fault systems in three states of the power system, and through MATLAB simulation.
Platform: | Size: 3368960 | Author: starcool | Hits:

[matlabCode1

Description: 3.Bifurcation analysis Bifurcation analysis has to be done for finding the different eigen values. eigen value plot has to be made for understanding the movement of the eigen values stable to unstable region to understand the stability of the system according to the change in system parameters.Bifurcation analysis has to be done for a 9-bus ,39 bus ,14bus,30 bus system with and without connecting squirrel cage induction generator to the system. single turbine generator has to be considered first and after that a wind farm with more than 10 turbine generators has to be connected -3.Bifurcation analysis Bifurcation analysis has to be done for finding the different eigen values. eigen value plot has to be made for understanding the movement of the eigen values stable to unstable region to understand the stability of the system according to the change in system parameters.Bifurcation analysis has to be done for a 9-bus ,39 bus ,14bus,30 bus system with and without connecting squirrel cage induction generator to the system. single turbine generator has to be considered first and after that a wind farm with more than 10 turbine generators has to be connected
Platform: | Size: 8192 | Author: Ravindran | Hits:

[OtherGreen-Energy-and-Technology

Description: Stability Augmentation of a Grid-connected Wind Farm
Platform: | Size: 14191616 | Author: homayun | Hits:

[VHDL-FPGA-Verilog05448528

Description: s a clean renewable energy, wind energy draws more and more attention around the world. In case of high wind speed or low speed but substantial installed wind power capacity, wind turbine generators (WTGs) will take the place of traditional power plant partly. Under the circumstance, the transient stability will change. Therefore, in this article, the synthetical dynamic model of WTG is introduced first, and on the basis of it, the article focus on the comparison of transient stability characteristic between wind farm based on double fed induction
Platform: | Size: 301056 | Author: phdscolar11 | Hits:

[SCM06547878

Description: This study presents wind turbine converter stability analysis of wind farms in frequency domain. The interaction between the wind turbine control system and the wind farm structure in wind farms is deeply investigated. Two wind farms (i.e. Horns Rev II and Karnice) are taken into consideration in this study. It is shown that wind farm components, such as long high-voltage alternating current cables and park transformers, can introduce significant low-frequency series resonances seen from the wind turbine terminals that can affect wind turbine control system operation and overall wind farm stability
Platform: | Size: 805888 | Author: phdscolar11 | Hits:

CodeBus www.codebus.net