Description: 基于单位功率因数控制策略的单相有源滤波,去掉非线性负载部分即为单相全控整流。开关器件采用IGBT。-Based on the unity power factor control strategy of single-phase active power filter, remove the part of non-linear load is the single-phase full-controlled rectifier. Switching device IGBT. Platform: |
Size: 7168 |
Author:雷宾 |
Hits:
Description: 3 phase Active Power filter that is simulated in matlab simulink based on hysteresis current control method Platform: |
Size: 16384 |
Author:khalilg |
Hits:
Description: A Comparative Performance Analysis of Four Control
Algorithms for a Three Phase Shunt Active Power Filter Platform: |
Size: 386048 |
Author:yasser |
Hits:
Description: Abstract—In this paper a current reference generation
method for a voltage source shunt active power filter is
examined. The proposed method improves the harmonic
filtering by compensating the delays in the system. In
stationary operating point of the load the method uses
measurement data sampled in previous periods to generate a
reference prediction. Since in transient state of the load the
prediction no longer holds true, a computational control delay
compensation algorithm is used in the reference generation
instead of the prediction in this situation. Changing the
algorithm according to the operating point guarantees effective
harmonic compensation in all operating points. In this paper
the system performance is examined with an active filter
simulation model. Platform: |
Size: 274432 |
Author:yasser |
Hits:
Description: 并联有源电力滤波器(APF)基于空间矢量的滞环控制-Shunt active power filter (APF) based on space vector control hysteresis Platform: |
Size: 1255424 |
Author:zhwb |
Hits:
Description: sigle phase active power filter using pll control technique
will work efficiently when supply is of distorted nature
ismp and ismp nature Platform: |
Size: 14336 |
Author:suren |
Hits:
Description: 有源电力滤波器模块,可以进行谐波抑制以及无功补偿,可以用于逆变器输出滤波器-Active power filter modules, the reactive power compensation and harmonic control, can be used for inverter output filter
Platform: |
Size: 15360 |
Author:智腾飞 |
Hits:
Description: 有源电力滤波器,用于实现无功治理与谐波补偿,精度很高-Active power filter for reactive power control and harmonic compensation, high accuracy Platform: |
Size: 12288 |
Author:hanwei |
Hits:
Description: 论文首先对有源电力滤波技术产生的背景!发展现状以及发展趋势作了详细的阐述,分析了有源电力滤波器的优点及其丰富的功能,除补偿谐波电流外,还可补偿基波无功!平衡三相电压!抑制电压闪变等"分析比较了有源电力滤
波器各种补偿电流跟踪控制方法,重点研究了空间电压矢量滞环控制和单周控制这两种控制方法
-Papers! Development status and trends detailed exposition of the first active power filter technology for the background, analyzes the advantages of APF and its wealth of features, in addition to the compensation of harmonic currents, but also compensate for the fundamental Reactive! balanced three-phase voltage! suppress voltage flicker and other " active power filters are analyzed and compared various compensation current tracking control method focuses on the space voltage vector hysteresis control and single-cycle control of these two control methods Platform: |
Size: 6181888 |
Author:huijuan |
Hits:
Description: Control of 3-level Shunt Active Power Filter
using Harmonic Selective Controller
Control of 3-level Shunt Active Power Filter
using Harmonic Selective Controller Platform: |
Size: 162816 |
Author:mo |
Hits:
Description: This paper describes different power quality
problems in distribution systems and their solutions with
power electronics based equipment. Shunt, hybrid and
series active power filters are described showing their
compensation characteristics and principles of operation.
Different power circuits topologies and control scheme for
each type of active power filter are analyzed. The
compensation characteristics of each topology with the
respective control scheme are proved by simulation and
experimentally. Platform: |
Size: 177152 |
Author:pavan |
Hits:
Description: This paper, focus on the study and design of a shunt active power (APF) filter for the compensation of harmonic currents and reactive power in polluted environment and under unbalanced network voltage. In APF design and control, p-q theory was often served as the basis for the calculation of compensation current. In this theory, the mains voltage was assumed to be an ideal source in the calculation process. However, in most of time and most of industry power systems, mains voltage may be unbalanced and/or distorted. For these reasons, we used a new technique with instantaneous power theory (p-q theory) based on Phase Locked Loop (PLL) in order to control APF under unbalanced mains voltage. A pulse width modulation (PWM) technique is used to generate the switching signals to the shunt APF.-This paper, focus on the study and design of a shunt active power (APF) filter for the compensation of harmonic currents and reactive power in polluted environment and under unbalanced network voltage. In APF design and control, p-q theory was often served as the basis for the calculation of compensation current. In this theory, the mains voltage was assumed to be an ideal source in the calculation process. However, in most of time and most of industry power systems, mains voltage may be unbalanced and/or distorted. For these reasons, we used a new technique with instantaneous power theory (p-q theory) based on Phase Locked Loop (PLL) in order to control APF under unbalanced mains voltage. A pulse width modulation (PWM) technique is used to generate the switching signals to the shunt APF. Platform: |
Size: 189440 |
Author:zakary |
Hits:
Description: 谐波抑制的一个重要趋势是采用有源电力滤波器,有源电力滤波器也是一种电力电子装置,且相关技术的研究也日渐成为研究的热点。本文阐述了几种常见APF的拓扑结构及各自的优缺点,详细分析了基于瞬时无功功率理论的谐波检测方法,比例控制和前馈控制两种电流环控制策略以及SPWM和SVPWM两种调制策略。-the harmonic suppression is an important trend of active power filters, active power filter is a power electronic devices, and related technologies are increasingly become a hot topic. This paper describes the topology and their advantages and disadvantages of several common APF, a detailed analysis of the harmonic detection method based on instantaneous reactive power theory, and proportional control and feedforward control of Platform: |
Size: 3980288 |
Author:zhangsan |
Hits:
Description: This paper proposes an effective control scheme
for three-phase three-wire (3P3W) active power filter using
neural-based harmonic identification scheme. To achieve
excellent steady state and dynamic response, the feedback
control plus feed-forward control structures is utilized in the
proposed control algorithms. The steady-state error minimization
is achieved by the feedback loop, where the proportional
integral regulators were adopted in d-axis and
q-axis of the synchronous rotating reference frame synchronized
with grid voltages by using the phase-locked loop. The
adaptive linear combiners are utilized in the feed-forward
loop, which serves the purpose of load disturbance rejection,
and it significantly enhances dynamic performance of active
power filter (APF). Platform: |
Size: 1275904 |
Author:samir |
Hits:
Description: In this paper, an efficient active power filter (APF) scheme is developed to estimate and compensate for harmonic distortion in an electrical power network. The developed APF control scheme is based on a double proportional feedback controller and a single-phase voltage-source half-wave bridge inverter. The proposed filter uses a Multi-layer Artificial Neural Network (MLANN) with a shift method for estimating system harmonic currents and voltages at a dedicated point. The proposed scheme is tested on a 13 bus industrial distribution system. The obtained results ensure the effectiveness of the proposed filter. The system is simulated in MATLAB-Simulink and simulation results prove that the polluting harmonics have been greatly reduced. Platform: |
Size: 1906688 |
Author:amir1 |
Hits: