[hospital software systemslaa274

Description: 测量脉搏和血氧浓度 使用 TI 公司的 MSP430 执行代码-Measurement of pulse and blood oxygen concentration using TI
Platform: | Size: 933443 | Author: 王石头 | Hits:

[SCMOSS

Description: 使用C8051F实现脉搏及血氧饱和度测量 包括均值滤波,微分阈值算法-C8051F to achieve the use of pulse and blood oxygen saturation measurements including mean filter, differential threshold algorithm
Platform: | Size: 190464 | Author: 李星 | Hits:

[hospital software systemslaa274

Description: 测量脉搏和血氧浓度 使用 TI 公司的 MSP430 执行代码-Measurement of pulse and blood oxygen concentration using TI
Platform: | Size: 932864 | Author: 王石头 | Hits:

[Windows DevelopRecognize

Description: 这是一个在windows平台下用vc++6.0开发的可以实时采集和显示人体血压波形并计算出高低压以及脉搏值的软件-This is a windows platform using vc++ 6.0 development can be real-time acquisition and display of human blood pressure waveform and calculate the value of high and low pressure and the pulse of the software
Platform: | Size: 1947648 | Author: owen | Hits:

[Embeded-SCM Developxxxxxxxxxxx

Description: 使用C8051F实现脉搏及血氧饱和度测量 包括均值滤波,微分阈值算法O-C8051F achieved using pulse and blood oxygen saturation measurements, including mean filter, differential threshold algorithm OSS
Platform: | Size: 163840 | Author: xie | Hits:

[File Formatkjhk

Description: 电子血压计工作原理和设计 统由恒流源、压力传感器、放大电路、带通滤波、二次放大、血压脉冲触发、液晶驱动器、键盘语音电路和单片机组成。-Electronic blood pressure monitors working principle and design of integration by the constant current source, pressure sensor, amplifier, band-pass filtering, the second amplification, blood pressure, pulse trigger, LCD drivers, keyboard, voice circuits and microprocessor component.
Platform: | Size: 202752 | Author: lainengjun | Hits:

[Software Engineeringasssss

Description: 本文在深入了解透射式血氧饱和度测定原理及其方法之后,首先明确用近 红外光谱法测定组织血氧饱和度时,无论是透射式检测手段还是反射式检测, 其依据的基本原理都是Lambert-Beer定律和组织中各成分对应不同波长光的 吸收系数的差异。在对检测到的完全反应血液中氧合血红蛋白和脱氧血红蛋白 含量变化的脉动分量的处理上,由于透射检测中的处理方法用于反射时灵敏度 降低,论文中提出了一种新的能更灵敏反应血氧变化的参量作为确定血氧饱和 度的依据。-This in-depth understanding of the transmission type blood oxygen saturation determination theory and method, first of all clear by Near Infrared Spectroscopy tissue oxygen saturation, either transmissive or reflective detection Shouduan Shi detection, based on the basic principles are Lambert-Beer law and the organization of various components corresponding to different wavelengths of light absorption coefficient of the difference. Detected in the complete reaction of the blood oxygenation changes in hemoglobin and deoxy-hemoglobin content of the pulse component of the treatment, due to transmission detection sensitivity when dealing with methods for reducing reflection, the paper proposes a new more sensitive response changes in blood oxygen parameters as the basis for determining blood oxygen saturation.
Platform: | Size: 2369536 | Author: zhaoshihai | Hits:

[Software Engineeringsao2_dsp

Description: 脉搏波的准确测量是实现血氧饱和度准确测量的基础。基于DSP的脉搏血氧饱 和度测量仪,采用数字信号处理算法,可取得良好的测量效果。针对脉搏波的测量, 本文提出了几种处理算法。-Accurate measurement of pulse wave is to achieve accurate blood oxygen saturation measurement. DSP-based pulse oxygen saturation measuring instrument, digital signal processing algorithms can achieve good measurement results. Pulse wave for measurement, this paper presents several processing algorithms.
Platform: | Size: 2797568 | Author: zhaoshihai | Hits:

[SCMAVR_microcontroller_blood_pressure_pulse_Device.ra

Description: AVR 单片机的血压、脉搏装置设计AVR microcontroller blood pressure, pulse Device-AVR microcontroller blood pressure, pulse device designed AVR microcontroller blood pressure, pulse Device
Platform: | Size: 193536 | Author: laf | Hits:

[Software Engineeringblood

Description: 由心电图的r波到血氧浓度图的波峰所产生的脉波传递时间换算出脉波传递速度,进一步换算出血压的变化量-R wave from the ECG to the peak oxygen concentration diagram of the pulse wave generated by the time translation of the pulse wave velocity, and further converted from the change in blood pressure
Platform: | Size: 402432 | Author: kouk23 | Hits:

[Bio-RecognizePULSEWAVEprograme

Description: 脉搏波的多处采集点的波形,可用来进行对比,或是进行血管建模,很适合初学者-The various collection points of pulse wave waveform, can be used to compare, or modeling of blood vessels, it is suitable for beginners
Platform: | Size: 16349184 | Author: lily | Hits:

[SCMAVR--blood-pressure--pulse-devices

Description: AVR单片机应用:利用AVR 设计出测试血压、脉搏的装置,具体介绍了电路的设计及思路;-AVR microcontroller applications: the use of AVR design a test of blood pressure, pulse devices, specifically designed and introduced the idea of ​ ​ the circuit
Platform: | Size: 288768 | Author: lixiansheng | Hits:

[Software Engineeringproject38_final_paper

Description: Photoplethysmograph by Sara Sieg and Bill Ziebold ECE 345 This project was to design and build a photoplethysmograph. This device can be used to determine heart rate using a volume measurement of blood in the arteries and capillaries. This is done by using low levels of infrared light to detect small changes in blood content in the tissues with each heartbeat. A light-emitting diode is used to transmit light into the skin. The iron content in the blood reflects the infrared. A receiver then detects the transmitted light. This information is processed and amplified to provide the pulse waveform. The output form the receiver is proportional to the amount of blood in the tissues. The software analyzes the data to determine a heart rate.-Photoplethysmograph by Sara Sieg and Bill Ziebold ECE 345 This project was to design and build a photoplethysmograph. This device can be used to determine heart rate using a volume measurement of blood in the arteries and capillaries. This is done by using low levels of infrared light to detect small changes in blood content in the tissues with each heartbeat. A light-emitting diode is used to transmit light into the skin. The iron content in the blood reflects the infrared. A receiver then detects the transmitted light. This information is processed and amplified to provide the pulse waveform. The output form the receiver is proportional to the amount of blood in the tissues. The software analyzes the data to determine a heart rate.
Platform: | Size: 1637376 | Author: djanuari | Hits:

[SCMpulse

Description: 8051單片機,彙編程序,利用紅外線偵測手指頭血液的變化,偵測脈搏-8051 assembler, the use of infrared detection of finger blood changes, the detection pulse
Platform: | Size: 916480 | Author: 卓瑞豐 | Hits:

[Software EngineeringUS9116-006-N

Description: US9116-006-N血压传感器 脉搏传感器-US9116-006-N blood pressure sensor pulse sensor.
Platform: | Size: 165888 | Author: 杨先生 | Hits:

[GUI DevelopAnsleServer

Description: windoes 上的心电显示,血压,脉搏血氧显示,TCP连接等-The windoes ECG, blood pressure, pulse oximeter displays TCP connection ...
Platform: | Size: 7277568 | Author: ansle | Hits:

[Bio-RecognizePTT-and--blood-presure

Description: 一种通过脉搏传输时间计算血压的算法,该算法简单可实现,可以用于连续测量血压。-A calculation by the pulse transmission time BP algorithm, the algorithm is simple can be realized, can be used for continuous measurement of blood pressure.
Platform: | Size: 168960 | Author: liusong | Hits:

[hospital software systemE-Hospital

Description: we are going to make the secure and automated work flow of the health care system. In our proposed system, we are using the body sensors to identify the range or limit (Blood pressure and heart pulse should be in limit). Else we can find manually and can enter into the system. The value or range will be validated and the report produced to the concerned doctor. If its crosses the limit or its looking like the serious condition that will automatically make the alert to the ambulance service with the address of the patient where he located
Platform: | Size: 8938496 | Author: senthil | Hits:

[Mathimatics-Numerical algorithmsBlood-Pulse-PPG

Description: 计算脉搏信号的方法 PPG 脉搏波速度计算 血压-Calculation of Blood Pulse Transit Time from PPG PPG pulse signal calculation method of pulse wave velocity calculation
Platform: | Size: 1545216 | Author: 段誉 | Hits:

[Windows CEPulse-Oximetry-with-AFE4490-master

Description: Hey, There! This a sketch of pulse oximetry using NJL5501r-reflectance phototransistor and Texas Instruments AFE4490- Analogue Front End. Pulse oximetry is a method to measure oxygen saturation in a blood that carried by haemoglobin. The pulse oximetry method has been widely used in most of medical procedure. Nowadays, the pulse oximetry method has been simplified using a small device with red and infrared LED and phototransistor which is available in portable size and affordable price, accurate and high efficiency. As this sketch is made by beginner programmer, feel free to critize an error, since the purpose of this repository is to learn.-Hey, There! This is a sketch of pulse oximetry using NJL5501r-reflectance phototransistor and Texas Instruments AFE4490- Analogue Front End. Pulse oximetry is a method to measure oxygen saturation in a blood that carried by haemoglobin. The pulse oximetry method has been widely used in most of medical procedure. Nowadays, the pulse oximetry method has been simplified using a small device with red and infrared LED and phototransistor which is available in portable size and affordable price, accurate and high efficiency. As this sketch is made by beginner programmer, feel free to critize an error, since the purpose of this repository is to learn.
Platform: | Size: 3072 | Author: micro torrent | Hits: