Welcome![Sign In][Sign Up]
Location:
Search - vhdl code for elevator control system

Search list

[VHDL-FPGA-VerilogDEMO22

Description: VHDL源程序,MAXPLUS 环境下运行,电梯控制系统-VHDL source code, under Operation Converter, elevator control system
Platform: | Size: 598016 | Author: liu | Hits:

[VHDL-FPGA-Veriloglift_code_verilog

Description: 实现一个4层楼的单电梯控制系统。门可以自动开关也可以手动开关。代码可综合,无多驱动现象。-Realize a 4-story single-elevator control system. Door can automatically switch can also manually switch. Code can be integrated, no more than drive the phenomenon.
Platform: | Size: 3072 | Author: 幻婳 | Hits:

[VHDL-FPGA-Veriloglift.vhd

Description: 用VHDL实现了电梯的模拟程序,实现了自动判断楼层,然后根据客户需求和楼层最近原则,实现自动判断上下行,还有报警,强制开门等功能-Achieved using VHDL elevator simulation program, to determine the realization of an automatic floor, and then based on the principle of demand and the floor recently, automatically determine the next line, as well as alarm, forced open the door and other features ~ ~
Platform: | Size: 1024 | Author: 董灏 | Hits:

[Software EngineeringVHDL_fire_alarm_detection

Description: vhdl source code of fire detection system/fire alarm system especially for high rise building? This among the requirement :- according to my "fire detection system for tall building" project by using Spartan 3E FPGA, the vhdl program need to include all of dis specification:- First of all, we ll put sensor/smoke detector each floor in the tall building. 1) alarm ll activated if the sensor/smoke detector sense a fire 2)at the same time, the actuator will activate in order to control such a elevator and any other machines in the building. 3)the controller will display which floor caught by fire and the sensor/smoke detector initial or current temperature. 4)If there is false alarm, we can stop it by push the reset button .-vhdl source code of fire detection system/fire alarm system especially for high rise building? This is among the requirement :- according to my "fire detection system for tall building" project by using Spartan 3E FPGA, the vhdl program need to include all of dis specification:- First of all, we ll put sensor/smoke detector each floor in the tall building. 1) alarm ll activated if the sensor/smoke detector sense a fire 2)at the same time, the actuator will activate in order to control such a elevator and any other machines in the building. 3)the controller will display which floor caught by fire and the sensor/smoke detector initial or current temperature. 4)If there is false alarm, we can stop it by push the reset button .
Platform: | Size: 1024 | Author: subin | Hits:

CodeBus www.codebus.net